Friedrich Floating Air Pro-Premiere FPHW091 Service & Parts Manual page 55

Single zone
Hide thumbs Also See for Floating Air Pro-Premiere FPHW091:
Table of Contents

Advertisement

Printed Circuit Board (Outdoor)
55
COMPONENTS TESTING
1
Terminal of reactor
2
Terminal of compressor
3
Terminal of DC fan
4
Heat Sink temperature sensor
5
PressureProtector
6
Compressor discharge
temperature sensor
7
Outdoor ambient temperature
sensor
8
Outdoor pipe temperature
sensor
9
Terminal of compressor
overload protector
1846941 Outdoor Unit Printed Circuit Board Identification
10
Terminal of electronic
expansion valve
11
DRED Function
12
Terminal of AC fan
13
Cool Valve terminal
14
Heater terminal
15
4‑way valve terminal
16
Terminal of communication
wire
17
Terminal of live wire
18
Terminal of neutral
Figure 614

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents