Page 1
Contact: Connor O’Neill Phone: 507-213-2030 EFCO Aluminum Contact: Duane Tuhy (local rep) Phone: 623-535-4070 Corporate Phone: 800-221-4169 Stanley Access Doors Servicer Phone: 1-888-DOOR-444 1-888-366-7444 3164 S. Country Club Dr. Ste #5 Mesa, Arizona 85210 Phone 480-705-4699 ● Fax 480-705-4799 Email:azglass@hotmail.com WEB: arizonaglassspecialists.com...
Page 2
3164 S. Country Club Dr. Ste. #5 Mesa, AZ 85210 Office 480-705-4699 Fax 480-705-4799 Operation/Maintenance Instructions & Parts List Installer: DATE: 7/15/16 Arizona Glass Specialists 3164 S. Country Club Dr #5 Mesa, AZ 85210 Job name: Center At Val Vista The following materials were supplied Products for the above named job.
Improperly Adjusted Door can cause injury and equipment damage. Inspect door operation daily using safety checklist in Owner’s Operation and Maintenance Manual and at door. Safety devices should be in place and operational Have door adjusted as recommended in Owner’s Operation and Maintenance Manual if necessary. Have door inspected at least annually by a Stanley *In this manual, the word “Caution” means that injury or property damage can result from failure to follow instructions. *The word “note” is used to indicate important steps to be followed or important differences in equipment. ...
To Our Customers: The purpose of this Owner’s Manual is to familiarize you with your automatic door system. It is essential that you “know your system”, how it operates, and that you recognize the importance of maintaining your door system in compliance with the industry standards for safety. It is your responsibility, as owner or caretaker of the equipment, to inspect the operation of your door system on a daily basis to ensure that it is safe for all users of the door. This manual will provide you with a description of the operation and maintenance requirements of your door system. It also provides the instructions for the “Daily Safety Check” procedure. It is recommended by Stanley Access Technologies LLC that the “Daily Safety Check” be performed at least once a day and after any power outage. Occasional observance of the doors as they are in use is also recommended. Should the door fail to operate as prescribed in the “Daily Safety Check”, or at any other time for any reason, do not attempt to repair or adjust the door. Discontinue operation of the door and call for service by a Stanley AAADM‐certified service technician. Our technicians are trained to service your door in accordance with applicable industry safety standards. Service Availability: Stanley Access Technologies LLC products are distributed through a nationwide network of Stanley‐ owned branch locations and authorized distributors that specialize in Sales, Installation and Service of automatic door systems. Our Service programs offer you ongoing support such as regularly scheduled preventive maintenance, or if required, emergency service 24 hours a day, 365 days a year. No matter where you are located, our technicians are only a phone call away. Should you need service on your door system our customer support hotline is available 24/7 at 1‐888‐DOOR‐444. Limited Warranty Stanley Access Technologies, LLC a Division of Stanley Black & Decker, Inc., warrants the installed door system against failure due to manufacture of substandard material or workmanship for one‐year beginning on the completed date of installation. Please review your Certificate of Warranty Agreement for your full Warranty. Compliance with Industry Standards Your door system was designed to the latest operating and safety standards as prescribed by ANSI/BHMA A156.10 and UL®325 requirements. It is important that: ...
Operation Function Switches: The function switches for the door operator are located on the underside of the door header or on the jamb of the stationary panel (see diagram). The function switches are: Power Switch – this switch is illuminated a red color when the power is on. This switch should not be turned off unless the door is being serviced. Auto/Close/Open Switch – this is a 3‐position switch that allows the door to function automatically (auto); stay closed and not function at all, but remain secure (close); or hold open indefinitely (open). Enter switch – If the “one‐way” feature is installed, this switch will change the mode of the door so that it will not open from the outside when the door is fully closed Reduced Opening Switch – if the “Reduced Opening” feature is installed, this switch will cause the door to open partially when activated. Emergency Breakout: In case of power failure or other emergency, our sliding doors “breakout” to provide a wide opening, so you’re always assured of a clear exit. Depending on your model, the number of panels that breakout varies. Break out means that if you push the leading edge of the sliding panel outward, as you would a swing door, the panel will unlatch and pivot outwards. This can be done at any point of the door’s normal slide path. If the doors are broken out, there is a switch that will disable automatic operation. The doors will not function automatically unless the panels are returned to their normal, operating position. Reset: If the door system loses power for any period of time, the controller in the header will have to reinitialize. Initialization the door will occur automatically during the first cycle of operation when power is restored and the door is not physically locked. The steps for a manual reset are as follows: 1. Turn “POWER” switch to “OFF” position (non‐illuminated) 2. Verify that none of the panels are “broken out”. (not aligned in door track) 3. Turn “AUTO/CLOSE/OPEN” switch to “AUTO” position. 4.
1. A full Daily Safety Check should be performed each day. 2. Check the door area for slipping or tripping hazards 3. If the door package contains a threshold, sweep floor track to remove dust and debris 4. Check all door panels for broken or cracked glass. If broken or cracked glass is detected, contact our call center at 888‐DOOR‐444 immediately. 5. As mentioned above, ensure that there are no bulletin boards, literature racks, displays, or other attractions that could impede the operation of the door panels. Cleaning Stanley Access Technologies recommends that you clean the automatic door system using the following procedure: 1. Glass – Clean with water and a cotton cloth or use Windex™ or other like‐product with a detergent and alcohol‐based cleaner. 2. Aluminum – Clean with a mixture of equal parts Windex or other like‐product and Simple Green™ All Purpose Cleaner and a cotton cloth. 3. DO NOT USE any product with Alkalide or other sodium‐based product as it could deteriorate the aluminum finish. Note: Stanley recommends a semi‐annual inspection / adjustment of your automatic door equipment to optimize its performance and to extend the life‐time of your purchase. ...
Automatic Sliding Door Decals Sliding doors servicing ingress or egress must be marked with directional decals. The arrow sign must be visible from the approach side and an international “DO NOT ENTER” must be visible from the other side. These door decals must be affixed on the door 58” +/‐5” from the finished floor. KNOWING ACT DOORS – The door shall have signage which says “AUTOMATIC DOOR – ACTIVATE SWITCH TO OPERATE” along with other required signage visible from each side of the door. Decals included: Decals Ordered Separately: P/N 413743 P/N 511164 P/N 511165 A “Daily Safety Check” decal has also been provided as a reminder that your automatic door equipment must be checked daily for safe operation. Affix this decal to the side of the jamb tube. Certain jurisdictions require “This Door Must Remain Unlocked When the Building is Occupied” decal affixed on all exit doors. This decal is not supplied as part of the decal kit. Troubleshooting and Hints PROBLEM: Door(s) will not operate (will not open or close) ACTION: Is the power switch on? If not, turn it on. If the power switch is on, the door(s) may need to be reset. This is done by turning the power switch to the “OFF” position. Wait a few seconds, turn back “ON” and allow the door to re‐tune itself. The door(s) will open and close very slowly in a search mode and, if possible, the door(s) should not be interrupted during the process. If traffic must go through, door(s) will open at ...
TERMINOLOGY DRAWING AND INDEX 1. Activating Zone – It is the detection pattern 8. Breakout – A term applied to describe the (zone) of approximately five feet deep and as ability to allow emergency egress through the wide as the clear door opening protected by the door(s) in a manner different from its normal motion sensor. When someone enters the zone, operation. In sliding doors, the sliding panel the control is actuated and the sliding door swings out. panels open. 9. Reset Door Panels from Breakout Position – 2. Emergency Egress Position (Breakout) ‐ The Push the swing out door panel(s) closed to their sliding door panel(s) swing outward for normal position. emergency egress. The door system is inoperative in this position. 10. Safety Zone – The area covered by motion sensors and threshold presence sensors. 3. Header – The top horizontal aluminum tube that contains the operating mechanism. 11. Sliding Door – A door sliding parallel with the wall or face of the building allowing access. 4. IN Door(s) – Designed for traffic into the ...
DAILY SAFETY CHECK For Your Customers’ Safety and Your Own Protection P e r f o r m T h i s S a f e t y C h e c k o n E a c h A u t o m a t i c S l i d i n g D o o r E a c h D a y A n d ...