Advertisement

061266A
Laminar Outlet (3/pkg, 1 key)
0.5 GPM (1.9 L/min)
061267A
Laminar Outlet (3/pkg, 1 key)
1.0 GPM (3.8 L/min)
061268A
Laminar Outlet (3/pkg, 1 key)
1.5 GPM (5.7 L/min)
061296A
Laminar Outlet (3/pkg, 1 key)
2.2 GPM (8.3 L/min)
NOTES:
For optimum performance of this product, the recommended
system pressure is between 20 and 80 PSI static. This
product will operate up to a maximum of 125 PSI static
per ANSI and CSA requirements. However, it is not
recommended the pressure go above 80 PSI. Thermal
expansion or leaking pressure reducing valves may require
the use of expansion tanks or relief valves to ensure your
system never exceeds its maximum intended pressure
setting.
Control Box #0 and #1
Designed for routine 180°F (82°C) disinfection cycles up to
10 minutes.
Control Box #8
High temperature disinfection cycles not recommended
for #8 control box as the thermostatic mixing valve limits
the higher temperature water flow output.
• Use 3-conductor 18AWG wire between transformer and
hardwire converter / driver board earth ground.
• Use Delta Commercial approved transformers and mount
the transformer a minimum of 6" (152 mm) away from the
Delta driver board enclosure.
• Refer to Proximity Application Notes on SpecSelect for
installation best practices, proper grounding and wiring
diagrams.
060905A
Cover Gasket
060906A
Surface
Mount Housing
061252A
Dual
Driver Board
063128A
Battery Box Assembly less driver
board and battery holder
COVER
060577A
060073A
12" Stainless Steel Cover
Screws (4/pkg) and driver bit for covers
PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as
items relating to ongoing maintenance suggestions and procedures are included.
063222A / 063222SS / 063222BL
Proximity Gooseneck Spout Assembly
0.5 GPM (1.9 L/min)
063226A / 063226SS / 063226BL
Proximity Gooseneck Spout Assembly
1.0 GPM (3.8 L/min)
063227A / 063227SS / 063227BL
Proximity Gooseneck Spout Assembly
1.5 GPM (5.7 L/min)
063229A / 063229SS / 063229BL
Proximity Gooseneck Spout Assembly
2.2 GPM (8.3 L/min)
061293A
Spacer package for
Proximity Gooseneck
062032A
Braided Polymer Hose
063127A
Solenoid Valve with 3/8"
Compression Connectors
and Solenoid Holder
060908A
Solenoid Holder
060909A
Screen Assembly
063131A
3/8" Comp Connect Nut & Ferrile
062032A
Braided Polymer Hose
w w w . s p e c s e l e c t . c o m
62__TP3__ __ __
Write purchase model number here for future reference
INSTALLATION AND SET-UP INSTRUCTIONS
Model Number
Description
621TPxxx0
Battery Operated Surface Mount Box #0
621TPxxx1TR
Battery Operated Control Box #1 Trim
621TPxxx8TR
Battery Operated Control Box #8 Trim
620TPxxx0
Hard Wire Operated Surface Mount Box #0
620TPxxx1TR
Hard Wire Operated Control Box #1 Trim
620TPxxx8TR
Hard Wire Operated Control Box #8 Trim
061294A
Single Hole
Deck Gasket
for Proximity
Gooseneck
(6/pkg)
RP6087
Nut & Washer
061206A
Proximity
Sensor Module
TMV Repair Kits
061137A
063164A
Adjustment Wrench
Check Valves (2/pkg)
Page 1
Page #
2
4
6
8
10
12
061269A
061269SS
061269BL
4" Deck Plate
& Holddown Pkg
061270A
061270SS
8" Deck Plate
& Holddown Pkg
061295A
Nut & Washer
060683A
24VAC to 6VDC Converter
061259A
Ground Wire Kit
(for hardwire models)
061047A
24VAC to 6VDC Converter with
Battery Backup
061256A
36" Sensor Module Extension Cable
OPTION LIST
060681A
Battery Holder
TRANSFORMERS
060704A
Transformer 110 to 24 VAC 20VA
up to 5 Electronic Valves
060771A
Transformer 110 to 24 VAC 40VA
up to 10 Electronic Valves
DECK PLATES
061269A / 061269SS / 061269BL
4" Deck Plate & Hold-Down Pkg
061270A / 061270SS
8" Deck Plate & Hold-Down Pkg
209989 Rev. B

Advertisement

Table of Contents
loading

Summary of Contents for Delta 62 TP3 Series

  • Page 1 • Use 3-conductor 18AWG wire between transformer and 061259A hardwire converter / driver board earth ground. Ground Wire Kit • Use Delta Commercial approved transformers and mount (for hardwire models) the transformer a minimum of 6” (152 mm) away from the 061294A Delta driver board enclosure.
  • Page 2: Installation And Set Up Instructions

    Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 621TPxxx0 Battery Operated Surface Mount Box #0 INSTALLATION AND SET UP INSTRUCTIONS Fig. 1 Spout STEP 1. FAUCET INSTALLATION Mount faucet to sink using the provided components in the following order - grey bottom spacer, washer, lock nut (Fig.
  • Page 3 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 621TPxxx0 Battery Operated Surface Mount Box #0 INSTALLATION AND SET UP INSTRUCTIONS STEP 8. TEST FOR OPERATION Test for operation. If OK, then close lid - Use caution not to damage wires or components on electronic driver board.
  • Page 4 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 621TPxxx1TR Battery Operated Control Box #1 Trim INSTALLATION AND SET UP INSTRUCTIONS STEP 1. ROUGH IN Typical Installation Fig. 7 (Recessed Mount Box) If recessed box is supplied, rough in as per Figure 8.
  • Page 5 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 621TPxxx1TR Battery Operated Control Box #1 Trim INSTALLATION AND SET UP INSTRUCTIONS Fig. 9 STEP 5. TEST FOR OPERATION Spout Test for operation. If OK, then close lid - Use caution not to damage wires or components on electronic driver board.
  • Page 6 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 621TPxxx8TR Battery Operated Control Box #8 Trim INSTALLATION AND SET UP INSTRUCTIONS STEP 1. ROUGH IN Typical Installation Fig. 12 (Recessed Mount Box) If recessed box is supplied, rough in as per Figure 13.
  • Page 7 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 621TPxxx8TR Battery Operated Control Box #8 Trim INSTALLATION AND SET UP INSTRUCTIONS STEP 5a. CONNECT ELECTRICAL SUPPLY, Fig. 14 SOLENOID VALVE & SENSOR Spout Towards Towards...
  • Page 8 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 620TPxxx0 Hard Wire Operated Surface Mount Box #0 INSTALLATION AND SET UP INSTRUCTIONS Fig. 19 Spout STEP 1. FAUCET INSTALLATION Mount faucet to sink using the provided components in the following order - grey bottom spacer, washer, lock nut (Fig.
  • Page 9 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 620TPxxx0 Hard Wire Operated Surface Mount Box #0 INSTALLATION AND SET UP INSTRUCTIONS CONDUCTIVE SINKS NON-CONDUCTIVE SINKS Fig. 24 Fig. 25 Metal Sink Mounting Hardware or Bracket Sink Ground...
  • Page 10 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 620TPxxx1TR Hard Wire Operated Control Box #1 Trim INSTALLATION AND SET UP INSTRUCTIONS STEP 1. ROUGH IN Typical Installation Fig. 27 (Recessed Mount Box) Note: Wires connecting between box(es) and from transformer must be protected from abrasion and being pulled at connections.
  • Page 11 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 620TPxxx1TR Hard Wire Operated Control Box #1 Trim INSTALLATION AND SET UP INSTRUCTIONS Cover STEP 4a. CONNECT ELECTRICAL SUPPLY, Fig. 29 SOLENOID VALVE AND SENSOR Valve Spout Spacer...
  • Page 12: Step 2. Faucet Installation

    Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 620TPxxx8TR Hard Wire Operated Control Box #8 Trim INSTALLATION AND SET UP INSTRUCTIONS STEP 1. ROUGH IN Typical Installation Fig. 34 (Recessed Mount Box) Note: Wires connecting between box(es) and from transformer must be protected from abrasion and being pulled at connections.
  • Page 13 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 620TPxxx8TR Hard Wire Operated Control Box #8 Trim INSTALLATION AND SET UP INSTRUCTIONS STEP 5a. CONNECT ELECTRICAL SUPPLY, Fig. 36 SOLENOID VALVE AND SENSOR Spout Towards Towards...
  • Page 14 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 620TPxxx8TR Hard Wire Operated Control Box #8 Trim INSTALLATION AND SET UP INSTRUCTIONS STEP 7. BASIC OPERATION AFTER CALIBRATION Proximity sensing technology works by creating an electrical field around a conductor (the spout) and monitoring the change in capacitance ®...
  • Page 15: Making Adjustments

    ● bAd - Replace Batteries (buzzer will annunciate and LED will blink if activated - if these features are turned on) If you have any questions about the installation of this product or need help troubleshooting this product, please call Delta Commercial Technical Services at 1-800-387-8277 (Canada) or 1-877-509-2680 (U.S.A.).
  • Page 16: Care Instructions

    CARE INSTRUCTIONS This Delta Commercial faucet is designed and engineered in accordance with the highest quality and performance standards. With proper care, it will give years of trouble free service. Care should be given to the cleaning of this product. Although the chrome finish is extremely durable, it can be DAMAGED by ACIDIC CLEANERS (i.e.
  • Page 17 TROUBLESHOOTING GUIDE Check to ensure faucet was installed Note: See attached M&I, pages 1 to 15. according to the M&I sheet. Test for operation. If unit does not Verify spacers are in place; black spacer on top and grey spacer on the operate: bottom of the sink or counter.
  • Page 18 Delta Commercial Faucet Limited Warranty All parts of the Delta® HDF® and TECK® faucets are warranted to the original consumer purchaser to be free from defects in material, finish and workmanship for a period of five (5) years unless otherwise specifically stated in the catalogue and price book. This warranty is made to the original consumer purchaser and shall be effective from date of purchase as shown on purchaser’s receipt.

Table of Contents