96 Technical data

Ratings

ACS880-
Frame
Resistor values
604-...
size
R
min
Ohm
U
= 400 V
N
0500-3
R8i
1.7
0750-3
R8i
1.2
1000-3
2×R8i
1.7
1510-3
2×R8i
1.2
2260-3
3×R8i
1.2
3010-3
4×R8i
1.2
3770-3
5×R8i
1.2
U
= 500 V
N
0630-5
R8i
2.2
0940-5
R8i
1.4
1260-5
2×R8i
2.2
1880-5
2×R8i
1.4
2830-5
3×R8i
1.4
3770-5
4×R8i
1.4
4710-5
5×R8i
1.4
U
= 690 V
N
0870-7
R8i
3.0
1300-7
R8i
2.0
1730-7
2×R8i
3.0
2600-7
2×R8i
2.0
3900-7
3×R8i
2.0
5200-7
4×R8i
2.0
6500-7
5×R8i
2.0
No overload use
R
I
I
max
1
2
Ohm
A DC
A DC
2.1
781
310
1.4
1171
465
2.1
1562
621
1.4
2342
931
1.4
3514
1396
1.4
4685
1862
1.4
5856
2327
2.6
781
310
1.7
1171
465
2.6
1562
621
1.7
2342
931
1.7
3514
1396
1.7
4685
1862
1.7
5856
2327
3.6
781
310
2.4
1171
465
3.6
1562
621
2.4
2342
931
2.4
3514
1396
2.4
4685
1862
2.4
5856
2327
Ratings with R
min
Cyclic load (1 min / 5 min)
P
I
I
contmax
max
dc
(S
)
n
kW
A DC
A DC
(kVA)
500
370
999
750
555
1499
1000
740
1998
1510
1110
2997
2260
1665
4496
3010
2220
5994
3770
2775
7493
630
370
999
940
555
1499
1260
740
1998
1880
1110
2997
2830
1665
4496
3770
2220
5994
4710
2775
7493
870
370
999
1300
555
1499
1730
740
1998
2600
1110
2997
3900
1665
4496
5200
2220
5994
6500
2775
7493
I
P
rms
br
A DC
kW
351
640
527
960
702
1290
1053
1930
1580
2890
2106
3860
2633
4820
351
800
527
1210
702
1610
1053
2410
1580
3620
2106
4820
2633
6030
351
1110
527
1660
702
2220
1053
3330
1580
4990
2106
6650
2633
8320