11. Safety devices

Type of
protection
Current fuse (Main PCB)
Circuit protection
Current fuse (Wire)
Fan motor
Thermal protection
protection
program
Thermal protection
program
(Discharge temp.)
Compressor
Thermal protection
protection
program
(Outdoor temp.)
(Only in COOL or DRY
mode)
Protection form
Activate
Reset
Activate
Reset
Activate
Reset
- 48 -
Model
AOYG09KHCAN AOYG12KHCAN AOYG14KHCAN
250 V, 25 A
250 V, 5 A
250 V, 3.15 A
250 V, 3.15 A
125 ±10 °C
Fan motor stop
120 ±10 °C
Fan motor restart
110 °C
Compressor stop
After 7 minutes
Compressor restart
-15 °C
Compressor stop
-10 °C
Compressor restart