Troubleshooting Guide; Troubleshooting - Stihl HSA 45 Instruction Manual

Hide thumbs Also See for HSA 45:
Table of Contents

Advertisement

Available languages

Available languages

English

21 Troubleshooting Guide

21.1 Troubleshooting

Always remove the activation key before carrying out any inspection, cleaning or maintenance.
Condition
LEDs on the
Hedge Trimmer
3 LEDs flash
red.
Hedge trimmer does
not start when
switched on.
1 LED flashes
green.
3 LEDs glow
red.
Hedge trimmer cuts
3 LEDs glow
out during operation.
red.
Runtime is too short.
Hedge trimmer is not
3 LEDs glow
being charged.
red.
28
Cause
Remedy
Malfunction in hedge
► Do not attempt to use. The hedge trimmer has a malfunction
trimmer.
and must be checked by a servicing dealer.
Activation key not
► Remove the activation key, @ 12.2.
fully inserted.
► Visually check the electrical contacts of the activation key.
► Reinsert the activation key, @ 12.1.
Less than 20%
► Charge the hedge trimmer, @ 10.
charge remaining.
Integrated battery
► Remove the activation key, @ 12.2.
too hot.
► Allow the hedge trimmer to cool down gradually at ambient
temperatures of about 50 °F to 68 °F (10 °C to 20 °C).
Moisture in hedge
► Allow the hedge trimmer to dry.
trimmer.
Integrated battery
► Remove the activation key, @ 12.2.
too hot.
► Allow the hedge trimmer to cool down gradually at ambient
temperatures of about 50 °F to 68 °F (10 °C to 20 °C).
Electrical
► Switch off the hedge trimmer. Wait at least 5 seconds and
malfunction.
switch it back on, @ 13.
Hedge trimmer not
► Charge the hedge trimmer, @ 10.
fully charged.
Useful life of
► Have the hedge trimmer checked by an authorized STIHL
integrated battery
servicing dealer.
has been reached or
exceeded.
Integrated battery
► Allow the hedge trimmer to warm up or cool down gradually
too hot / too cold.
at ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
Integrated battery
► Allow the hedge trimmer to warm up or cool down gradually
too hot / too cold.
at ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
► Operate the charger only in enclosed, dry rooms at ambient
temperatures of 32 °F to 104 °F (0 °C to 40 °C).
21 Troubleshooting Guide
0458-717-8221-A

Advertisement

Table of Contents
loading

Table of Contents