Download Print this page

Samsung AC160JNH KH Series User Manual page 9

Duct type

Advertisement

Checking before use
Type
Against cold air
De-ice cycle
(Defrost cycle)
Anti-protection of
internal battery
Protect compressor
• I f the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from an outdoor unit that may
have deposited at low temperatures.
NOTE
The internal fan is switched of automatically and restarted only after the de-ice cycle is completed.
Tips on using air conditioner
Here are some tips that you would follow when using your air conditioner.
TOPIC
Cooling
Heating
Frost & De-ice
Fan
10
The internal fan will be of to against cold air when the heat pump is heating.
The internal fan will be of to against cold air when the heat pump is heating.
The compressor will be of to protect internal battery when the air conditioner operates
in Cool mode.
The air conditioner does not start operating immediately to protect the compressor of
the outdoor unit after it has been started.
RECOMMENDATION
• I f current outside temperatures are much higher than the selected
indoor temperature, it may take time to bring the inner temperature
to the desired coolness.
• A void drastically turning down the temperature. Energy is wasted and
the room does not cool faster.
• S ince the air conditioner heats the room by taking heat energy
from outdoor air, the heating capacity may decrease when outdoor
temperatures are extremely low. If you feel the air conditioner
insuiciently heats, using an additional heating appliance in
combination with the air conditioner is recommended.
• W hen the air conditioner runs in Heat mode, due to temperature
diference between the unit and the outside air, frost will form.
If this happens:
- The air conditioner stops heating.
- The air conditioner will operate automatically in De-ice mode for 10 minutes.
- The steam produced on the outdoor unit in De-ice mode is safe.
No intervention is required; after about 10 minutes, the air conditioner
operates again normally.
 The unit will not operate when it starts to de-ice.
• F an may not operate for about 3~5 minutes at the beginning to
prevent any cold blasts while the air conditioner is warming up.