29 IN. (73.7 CM) LONG VENT ELECTRIC DRYER
PARA LA SECADORA ELÉCTRICA CON DUCTO DE ESCAPE
DRYER SAFETY ............................................... 1
INSTALLATION INSTRUCTIONS .................... 2
Tools and Parts.............................................. 2
Location Requirements ................................ 2
Electrical Requirements................................. 3
Electrical Connection..................................... 4
Venting Requirements ................................... 8
Plan Vent System .......................................... 8
Install Vent System ...................................... 10
Install Leveling Legs .................................... 10
Level Dryer................................................... 10
Connect Vent ............................................... 10
Reverse Door Swing (Optional) ................... 10
Complete Installation................................... 11
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
8535899

INSTALLATION INSTRUCTIONS

INSTRUCCIONES DE INSTALACIÓN
DE 29 PULG. (73,7 CM) DE LARGO
Table of Contents / Índice

DRYER SAFETY

Your safety and the safety of others are very important.
DANGER
SEGURIDAD DE LA SECADORA........................12
Herramientas y piezas.......................................12
Requisitos de localización ................................ 12
Requisitos eléctricos ......................................... 13
Conexión eléctrica.............................................15
Requisitos de ventilación ..................................19
Nivelación de la secadora................................. 23
Conexión del ducto de escape......................... 23
Complete la instalación.....................................24
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool 8535899

  • Page 1: Table Of Contents

    All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. 8535899 Table of Contents / Índice SEGURIDAD DE LA SECADORA...12 INSTRUCCIONES DE INSTALACIÓN ...12...
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS Tools and Parts Check that you have everything necessary for correct installation. Proper installation is your responsibility. Flat-blade screwdriver Adjustable wrench that opens to 1 in. (2.5 cm) or hex-head socket wrench (for adjusting dryer feet) Level #2 Phillips screwdriver Vent clamps Parts supplied: Remove parts package from dryer drum.
  • Page 3: Electrical Requirements

    Companion appliance spacing should also be considered. " " " " " 1. Recessed area 2. Side view - closet or confined area 3. Closet door with vents Mobile Home-Additional Installation Requirements This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and...
  • Page 4: Electrical Connection

    Power Supply Cord WARNING Fire Hazard Use a new UL approved 30 amp power supply cord. Use a UL approved strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center terminal (silver). Ground wire (green or bare wire) must be connected to green ground connector.
  • Page 5 Electrical Connection Options If your home has: And you will be connecting to: 4-wire receptacle A UL listed, 120/ (NEMA Type 14-30R) 240 volt minimum, 30 amp., dryer power supply cord* 4-wire direct A fused disconnect or circuit breaker box* 5"...
  • Page 6 Strip 5 in. (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5 in. (12.7 cm). Cut 1 remaining wires. Strip insulation back 1 in. (2.5 cm). Bend ends of wires into a hook shape. When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw.
  • Page 7 3-wire connection: Direct Wire Use where local codes permit connecting cabinet-ground conductor to neutral wire. Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed. Strip 3 in. (8.9 cm) of outer covering from end of cable. Strip insulation back 1 in.
  • Page 8: Venting Requirements

    4 in. (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFE™ venting products are recommended. DURASAFE™ vent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories. For more information, see the “Assistance or Service” section of your “Dryer User Instructions.”...
  • Page 9 Periscope Installation (For use with dryer vent to wall vent mismatch): Part Number 4396037 - 0 in. (0 cm) to 18 in. (45.72 cm) mismatch Part Number 4396011 - 18 in. (45.72 cm) to 29 in. (73.66 cm) mismatch Part Number 4396014 - 29 in. (73.66 cm) to 50 in. (127 cm) mismatch Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible...
  • Page 10: Install Vent System

    Vent Length Chart - 11 ft (3.4 m) to 25 ft (7.6 m) No. of Length of Flexible Metal Vent turns or elbows 11-15 ft 16-20 ft (3.4-4.6 m) (4.9-6.1 m) 75 ft 60 ft (22.9 m) (18.3 m) 65 ft 50 ft (19.8 m) (15.2 m)
  • Page 11: Complete Installation

    4. Use a small, flat-blade screwdriver to carefully remove 4 hinge hole plugs (4) on left side of cabinet. Insert plugs in hinge holes on right side of cabinet. 5. Insert screws in bottom holes on left side of cabinet. Tighten screws halfway.
  • Page 12: Seguridad De La Secadora

    INSTRUCCIONES DE INSTALACIÓN PARA LA SECADORA ELÉCTRICA CON DUCTO DE ESCAPE DE 29 PULG. (73,7 CM) DE LARGO SEGURIDAD DE LA SECADORA Su seguridad y la seguridad de los demás es muy importante. Hemos incluido muchos mensajes importantes de seguridad en este manual y en su electrodoméstico. todos los mensajes de seguridad.
  • Page 13: Requisitos Eléctricos

    Un contacto con conexión a tierra ubicado a unos 2 pies (61 cm) de cualquiera de los lados de la secadora. Vea “Requisitos eléctricos”. Un piso resistente para soportar la secadora con un peso total (secadora y carga) de 200 lbs (90,7 kgs). Asimismo se debe considerar el peso de otro artefacto que la acompañe.
  • Page 14 Conexión eléctrica Para instalar su secadora adecuadamente, usted debe determinar el tipo de conexión eléctrica que va a usar y seguir las instrucciones que aquí se proveen para el caso. Si los códigos locales no permiten la conexión de un conector para conexión a tierra del equipo al alambre neutro, vea “Conexión opcional de 3 hilos”.
  • Page 15: Conexión Eléctrica

    Cable de suministro eléctrico ADVERTENCIA Peligro de Incendio Use un cable de suministro eléctrico nuevo de 30 amperes con aprobación UL. Use un protector de cables con aprobación UL. Desconecte el suministro eléctrico antes de hacer las conexiones eléctricas. Conecte el alambre neutro (el blanco o el del centro) al terminal central (plateada).
  • Page 16 Opciones para la conexión eléctrica Si su casa tiene: Y usted va a conectar con: Un contacto de 4 Un cordón de hilos (Tipo NEMA suministro 14-30R) eléctrico para secadora, aprobado de UL, de 120/240 voltios mínimo y 30 amperios* Cable directo de 4 hilos desconectador...
  • Page 17 Conexión de 4 hilos: Cable directo IMPORTANTE: Se necesita una conexión de alambre de cuatro hilos para las casas rodantes y para los casos en que los códigos locales no permitan el uso de conexiones de 3 hilos. El cable de conexión directa debe tener 5 pies (1,52 m) extra de largo para poder mover la secadora si fuese necesario.
  • Page 18 Conexión de 3 hilos: Cable de suministro eléctrico Uso cuando los códigos locales permitan la conexión del conductor de tierra del gabinete al hilo neutro: 1. Contacto de 3 hilos (NEMA tipo 10-30R) 2. Enchufe de 3 hilos 3. Terminal de conexión a neutro 4.
  • Page 19: Requisitos De Ventilación

    3. Coloque los extremos enganchados de los otros hilos del cable de suministro eléctrico debajo de los tornillos exteriores del bloque de terminal (con los ganchos mirando hacia la derecha). Apriete y junte los extremos enganchados. Apriete los tornillos. 4. Apriete los tornillos del protector de cables. 5.
  • Page 20: Planificación Del Sistema De Ventilación

    Los productos de ventilación DURASAFE™ pueden comprarse en su distribuidor o llamando a Piezas y Accesorios Whirlpool. Para obtener más información tome como referencia la sección “Ayuda o servicio técnico” de sus “Instrucciones para el usuario de la secadora”. La salida de la secadora no debe conectarse en ningún ducto de escape de gas, chimenea, pared, techo o el espacio oculto de un edificio.
  • Page 21 NOTA: Se pueden adquirir los siguientes juegos para instalaciones alternas en espacios limitados. Por favor tome como referencia la sección “Ayuda o Servicio Técnico” de sus “Instrucciones para el usuario de la secadora”. Instalación en la parte superior: Pieza número 4396028 Instalación de periscopio (Para usar si hay desacoplo entre el ducto de escape de la pared y el conducto de ventilación de la secadora):...
  • Page 22: Instalación Del Sistema De Ventilación

    Cuando use una combinación de ductos de metal rígidos y flexibles: Use los cuadros siguientes para ayudarle a determinar la longitud máxima de ductos basada en el número de codos de 90° que necesitará. Determine el número de codos y vueltas que necesitará. Determine la longitud del ducto de metal flexible completamente extendido que va a usar.
  • Page 23: Nivelación De La Secadora

    Nivelación de la secadora Revise la nivelación de la secadora. Verifique primero de lado a lado y luego del frente hacia atrás. Si la secadora no está nivelada, apuntale la secadora, usando un bloque de madera. Use una llave de tuercas para regular las patas hacia arriba o hacia abajo y verifique nuevamente si la secadora está...
  • Page 24: Complete La Instalación

    Este olor es común cuando se usa por primera vez el elemento de calefacción. El olor desaparecerá. Benton Harbor, Michigan 49022 TM DURASAFE is a trademark of Whirlpool, U.S.A. TM DURASAFE es una marca de comercio de Whirlpool, EE.UU. Complete la instalación Impreso en EE.UU. 3/03...