Pump Maintenance - Pentair Pool Products Hydromatic H3HX Series Installation And Service Manual

Submersible pump with hazardous location motor end
Table of Contents

Advertisement

Pump
Operations
8. Turn switches to Auto position,
and pumps should start and
op er ate together until level
drops to turn-off point.
9. Repeat this operation cycle
sev er al times before leaving
the job.
10.Check voltage when pumps
are operating, and check the
amp draw of each pump.
Check amps on each wire as
sometimes a high leg will
exist.
One
leg
some what higher by 5 to 10
per cent without causing trouble.
For excessive amp draw on
one leg, the electric utility
company should be consulted.
Pump
Maintenance
As the motors are oil filled, no
lubrication or other main te nance
is re quired.
If the heat sensor and seal failure
are hooked up properly, no
attention is necessary as long as
the seal failure indicator light
doesn't come on. To ensure
continuity of the seal sensor leads,
a test light is provided on
in trin si cal ly safe Hydromatic
panels as standard equipment.
Pump should be checked every
quar ter for cor ro sion and wear.
Servicing Instructions:
IMPORTANT:
Read
directions
before
any parts.
WARNING: Before handling
these pumps and controls, always
dis con nect the pow er first.
Do not smoke or use sparkable
elec tri cal devices or flames in a
septic (gaseous) or possible
septic sump.
Field Service on Hydromatic
Hazardous Location Pumps:
If
a
Hydromatic
location pump is used in a
hazardous location the pump must
be returned to the factory for
service.
integrity of the hazardous location
rating of the pump and com ply
can
be
with our warranty re quire ments.
Pumps out of warranty and not
used in a hazardous location can
be field serviced by any reputable
serviceman. When any field
servicing is per formed on a pump,
the fol low ing in struc tions should
be followed care ful ly.
Disconnecting Pump Cords:
If
a
Hydromatic
location pump is to be removed
from its lo ca tion, one of two ways
may be used to disconnect the
pump cords from the rest of the
system.
Pump cords may be disconnected
at control panel (on sump mounted
con trol panels) and cord as sem bly
taken with pump.
CAUTION: If cord openings
from sump to con trol panel are
open, gas es from sump could
enter panel and an explosive
condition could ex ist.
all
Pump cords may be disconnected
replacing
at pump by removing the cord and
cap assembly, unplugging sensor
wires, and re mov ing wire nuts.
hazardous
This will ensure the
hazardous
After
removal
from
reinstall wire nuts in cord and cap
assembly and install protective
cover.
CAUTION: Do not reconnect
pow er to a cord and cap
assembly while removing from
pump.
Replacing Cords:
The
power
cord
sensor - seal failure cord is potted
into the con nec tion box cap,
forming
the
cord
assembly.
If cords require replacement due
to damage or cords being too
short, cord and cap assembly
must be replaced as a complete
assembly avail able from factory.
1. Remove
cord
assembly from con nec tion
box.
2. Disconnect wires taking note
of color/num ber coding.
3. Connect wires of new cord
and cap as sem bly in the same
manner as the old one was
removed.
4. Check
for
moisture
dryout.
5. Reinstall cord and cap assembly
on con nec tion box taking care
not to pinch wires.
6. Check
pump
for
rotation before re turn ing to
normal service.
Replacing Stator:
If motor winding is burned or
shorted, it can be rewound or
replaced with new factory wound
sta tor. Refer to sectional drawing
of pump and motor, and use the
following steps to remove and
replace stator.
pump,
and
heat
and
cap
and
cap
and
proper
5