KC2S(AKC2)/KE2S(AKE2)
INSTALLATION
1. Panel installation
1) One-touch installation type
Panel (thickness:
1 to 4.5mm
.039 to
.177inch)
Note: When installing to a 4.5mm .177 thick panel, remove the
rubber spacer first.
1. Panel installation
1) Installation using plastic magnet
Attach the unit to the equipment case.
Note: Take careful note of the precautions for use in the catalog or user's manual before using an Eco-COUNT METER or Eco-HOUR METER installed by one of the methods described above.
3. Terminal layout and wiring diagrams
(Common to Eco-COUNT METER and Eco-HOUR METER)
CT input
1
Notes: 1. Terminal 2 and 4 are connected inside.
2. The CT does not have polarity
OPTIONS
• Intermediate power cable (AKE2811)
Note: We recommend using an intermediate power cable when attaching the dedicated CT to a non-"Y" split power cable
EXPLANATION OF OPERATION
KC2S Eco-COUNT METER
1. The number of power-ons is counted by
sending through current through the
dedicated CT.
2. When the number of power ons
(measured value) reaches the full scale,
it reverts to 0, and starts counting again
from 0.
2) Installation frame type
Mounting screws
(attached to
mounting frame)
Rubber spacer
Panel (thickness:
1 to 4.5mm
(attached)
2) Installation via double-sided tape
Use this method in places where a plastic
magnet cannot be used or where installation
strength is insufficient.
Reset input
or
2
3
4
±10
200
±.394
7.874
3. When the reset terminal input is set to
on, the display will read "0". This does not
count during reset input.
Power on detection of
Mounting frame
ATH3803
(attached)
Rubber gasket
ATH3804
(attached)
.039 to
.177inch)
ON OFF
dedicated CT
Reset input
Count value
0
1
Note: ∗ If reset input is shut off while CT through current is on, the count will be set to 1.
26/03/2013
3) Panel cut-out dimensions
45
1.772
3) Installation via clamp
Clamp to one of the cables inside the
equipment, etc.
4. Use the reset key on the front of the unit
to reset manually. The display will be blank
while the reset key is being pressed.
2
99999999
0
1
Full scale
+0.6
0
+.024
0
+0.3
22.2
0
+.012
.874
0
ON
OFF
2
0
1
∗