Electrical Preparation - Bosch SHU53E Installation Instructions Manual

Bosch dishwasher installation instructions
Table of Contents

Advertisement

B
(533mm)
A
Figure 5/Ilus. 5
Figure 6/Ilus. 6
10
Electrical Preparation | Électricité | Preparación - Sistema Eléctrico
30"
(762mm)
21"

ELECTRICAL PREPARATION

WARNING: ELECTRICAL SHOCK
HAZARD - Working on an energized
circuit could result in serious injury or
death. Only qualified electricians
should perform electrical work. Do
not attempt any work on the dish-
washer electric supply circuit until
you are certain the circuit is de-
energized.
WARNING: FIRE HAZARD -
Improper electrical work can cause
fire. Only qualified electricians should
perform electrical work.
Electrical Supply
The customer has the responsibility of
ensuring that the dishwasher electrical
installation is in compliance with all
national and local electrical codes and
ordinances. The dishwasher is de-
signed for an electrical supply of 120V,
60 Hz, AC, connected to a dishwasher-
dedicated, properly grounded electrical
circuit with a fuse or breaker rated for
15 amps. If the dishwasher is con-
nected with a food disposer, a 20 amp
(and no higher) fuse or circuit breaker
may be used. Electrical supply conduc-
tors shall be a minimum #14 AWG
copper wire.
Regardless of where the electrical
supply cable enters the enclosure
(following the guidelines on page 8),
position the cable 21" (533mm) from
the enclosure's left side, as shown in
Figure 5, letter A. Extend the cable 30"
(762mm) from the enclosure's back, as
shown in Figure 5, letter B.
Remove 3" - 4" (75mm - 100mm) of the
cable's outer casing, as shown in
Figure 6, letter C, then remove 3/8" - 1/
2" (9 - 13mm) of insulation from each
conductor, as shown in Figure 6, letter
D.
Dishwasher Electrical Rating
V
l o
s t
H
r e
z t
1
2
0
6
0
E n g l i s h
A
m
p
e
e r
s
W
t a
1
4 ,
5
1
5
(
m
a
) x
s t
0

Advertisement

Table of Contents
loading

Table of Contents