◗ Remove the retaining frame.
◗ Clean the cutters and guards.
Do not clean more than one cutter and guard at
a time, since they are all matching sets. If you
accidentally mix up the cutters and guards, it may
take several weeks before optimal shaving
performance is restored.
◗ Remove the hairs with the brush supplied.
◗ Put the shaving heads back into the shaving
unit, put the retaining frame back into the
shaving unit, press the wheel and turn it
clockwise.
Cause 3: the shaving heads are damaged or worn.
B
◗ Remove the retaining frame.
◗ Remove the old shaving heads from the
shaving unit and replace them with new ones
Damaged or worn shaving heads (cutters and
guards) must only be replaced with the original
Philishave HQ53 shaving heads.
◗ Put the retaining frame back into the shaving
unit, press the wheel and turn it clockwise.