Advertisement

INSTALLATION MANUAL (HiE-SxxxSG/SI, IEC)
1. General Information
· This Installation manual contains information regarding the installation and the safe handling method
of the photovoltaic module (hereafter referred to as "module") supplied by Hyundai Energy Solutions
Co., Ltd. (hereafter referred to as "HES").
· HiE-SxxxSG: 340 pieces, 325-350W, 1500V
HiE-SxxxSI: 408 pieces, 395-420W, 1500V
· System users and installers should read and understand this manual before handling, installing the
module. Please contact Customer Support department or our local representatives for more detailed
information.
· Before installing solar photovoltaic systems, mechanical and electrical requirements for the total
system should be checked as well. Keep this manual in a safe place for future reference.
· The installer should consider every safety precautions specified in this manual and local codes when
installing a module.
· HES modules are tested and certified for installation worldwide. Different regions may have different
regulations for solar PV installations. In this manual, hereafter "IEC only" is used to refer to regions
where IEC standard applies, e.g. Europe, Middle East, most of Asia Pacific countries; "UL only" is
used to refer to regions where UL standard applies, e.g. United States, Canada; all other references
are global.
1.1
· Installing solar photovoltaic systems requires specialized skills and knowledge. Thus, before
installation, wiring, and operation of photovoltaic modules, system users and installer should
understand and conform to this manual.
· Installation and wiring should only be performed and supervised by qualified persons.
· Each module has a junction box for permanent cable connection. HES can provide customers with
fitted cables for easy installation. Installers should secure the safe installation status including all
electrical hazards.
1.2
· Installers should secure the installation status, without limitation, including the risk of electric shock.
· Backsheet of PV module should be kept safe from any damage or scratch to prevent mechanical or
electric shock.
· Do not disassemble or remove any part of a PV module. Such actions may cause electric shock, fire
or damage.
· Keep safety regulations for all components used in the system, including wiring and cables,
connectors, charging regulators, inverters, storage batteries and rechargeable batteries, etc.
Sales Office
4th Fl., First Tower,
55, Bundang-ro, Bundang-gu,
Seongnam-si, Gyeonggi-do,
13591 Korea
th
Issued on Sep. 17
, 2019
Page 1 of 13
www.hyundai-es.co.kr
Factory
313, Soi-ro, Soi-myeon, Eumseong-gun,
Chungcheongbuk-do 369-872, Korea

Advertisement

Table of Contents
loading

Summary of Contents for Hyundai HiE-S SG Series

  • Page 1 1. General Information · This Installation manual contains information regarding the installation and the safe handling method of the photovoltaic module (hereafter referred to as “module”) supplied by Hyundai Energy Solutions Co., Ltd. (hereafter referred to as “HES”). · HiE-SxxxSG: 340 pieces, 325-350W, 1500V HiE-SxxxSI: 408 pieces, 395-420W, 1500V ·...
  • Page 2: General Safety

    · Before installation, recommend preventing the module from exposure to direct sunlight or other light source. (If modules are exposed directly to sunlight without connection, each module generates over DC 30V, which is potentially hazardous.) · Modules are heavy. Be sure to have more than two persons with anti-slip gloves on carry each PV module.
  • Page 3: Transportation, Storage And Unpacking

    2. Transportation, Storage and Unpacking · Modules are packaged vertically. They should also be vertical during transportation. · Check tension of banding tapes before transportation. Be cautious of abnormal shock for vehicles and modules which might cause module damage and cell crack during transportation. Store the modules safely in a dry and cool environment.
  • Page 4: Installation Environment

    3. Installation Environment 3.1 General · Before installing and operating HES PV system, installer and operator should follow the requirements specified in this manual. · Do not drill additional holes in the frame of the modules. This additional hole will void the warranty.
  • Page 5: Installation

    1,000m (3,280ft) above sea level is permitted. ※ Installations under the condition of wind strength specified above are allowed only when the methods of installations comply with Module Installation Instruction (Appendix 1.) 2) Specific Site Condition The following actual site condition should be checked for adequate installations.
  • Page 6 Module M8 Screw Flat washer Spring washer The Support rail M8 Nut Picture 1. Installation Method using stainless steel bolt & nut The support rail Clamp A Clamp B Picture 2. Mounting Hardware (Clamp) Page 6 of 13 Factory...
  • Page 7: Module Wiring

    5. Wiring 5.1 General · All wiring should be matched with acceptable regional and local electrical codes. · All wiring work should be done by certified and authorized engineers. · All wiring should be connected safely in order to prevent any hazard.
  • Page 8 Picture 3. Grounding Hardware(Torque level: 2-3 N·m) 5.5 Module Terminations The installer should connect cables using the same cable connector equipped in each PV module. For more information about electrical connection, contact an authorized engineer of HES. HES does not give warranty for the case of using connectors which are not approved by HES.
  • Page 9 Picture 5. Connect connectors 9) If the connectors need to be disconnected, installer should use the exclusive tool to disconnect them after safety measure such as cut-off of connection band. 10) Connected cables and connectors should be fixed. 11) Action against contamination or corrosion should be enacted on disconnected connectors.
  • Page 10: Operation And Maintenance

    6. Operation and Maintenance It is required to perform regular inspection and maintenance of the modules, especially within warranty scope. It is the user’s responsibility to report to the supplier regarding the damages found. 6.1 Cautions · Do not conduct electrical work such as opening junction boxes or separation of connectors without a qualified expert.
  • Page 11: Disclaimer Of Liability

    7. Disposal · Users shall dispose of modules according to local disposal regulations. · Contact HES for more detailed information related to disposal and recycling. Disclaimer of Liability 1) HES do not have any responsibility and liability for clause as below.
  • Page 12: Appendix 1) Module Installation Instruction

    Appendix 1) Module Installation Instruction (Front / Back Design Load, Safety factor = 1.5) Method Overlap of Clamp with Al frame Overlap of Clamp with Al frame : 8-10mm : 9-11mm Bolting 4 Bolts : 1600/1600 Pa 8 Bolts : 3600/1600 Pa A: 330±50mm...
  • Page 13: Appendix 2) Module Electrical Performance

    Appendix 2) Module Electrical Performance · Electrical Characteristics : HiE-SxxxSG HiE-SxxxSG Item (xxx: Maximum Power Value) Maximum Power at STC(Pmax) [W] Voltage at Pmax (Vmpp) [V] 37.6 37.5 37.4 37.3 37.2 37.1 Current at Pmax (Impp) [A] 9.31 9.20 9.09...

This manual is also suitable for:

Hie-s si series