Step 7 Configuration; Hardware Settings - Siemens SIMATIC Mobile Panel 277 IWLAN Application Description

Evaluate through which access point the mobile panel communicates, evaluating an access point clients list
Table of Contents

Advertisement

5 Configuration Process

5.2 STEP 7 configuration

5.2
STEP 7 configuration
The standard configuration for the
Mobile Panel 277F IWLAN is the basis for the configuration.
The standard configuration was expanded by the functionality to evaluate the
"Clients list" of two access points and by a second mobile panel
(Mobile Panel 277F IWLAN RFID).
The enclosed sample project contains all necessary settings and blocks.
A detailed description of the standard configuration can be found in the
Note
"Configuration and use of mobile panel 277F IWLAN" application description
under the entry ID 25702331.
5.2.1

Hardware settings

Below, the expansions in relation to the standard configuration are described.
The following hardware was additionally added.
CP 343-1
Mobile Panel 277F IWLAN RFID
Adding the CP 343-1
Table 5-3
No.
1.
Adding the CP 343-1:
From the hardware catalog of the HW config
insert a CP 343-1, by dragging it into the rack
on slot 4 using "Drag&Drop"
The CP can be found in the hardware catalog
under "SIMATIC 300 > CP-300 > Industrial
Ethernet > CP 343-1"
Note:
ensure that you use the mobile panel you
have inserted!
In this example:
6GK7 343-1EX30-0XE0
32
Action
Screens
Evaluating An Access Point Clients List
V1.0, Entry ID: 48946495