Download Print this page

Installing Dsl Cards - Paradyne Hotwire 8775 Installation Instructions Manual

Msdsl termination unit
Hide thumbs Also See for Hotwire 8775:

Advertisement

Cables You Need

Installing DSL Cards

8775-A2-GZ40-00
The following customer-provided cables are used with this product.
For the network connection:
Plug-ended Telco 50-pin cable for connection from the Hotwire 8600 DSLAM
LINE port or one of the Hotwire 8800 DSLAM LINES ports to the Main
Distribution Frame (MDF) or other demarcation point.
For the DTE connection, one of the following:
100-pin plug to four DB15 (X.21)
100-pin plug to four DB25 (EIA-530A)
100-pin plug to four DB37 (RS-449)
100-pin plug to four MS34 (V.35)
See Technical Specifications on page 2 for part numbers of the DTE cables. For
more information refer to Appendix D, Cables and Pin Assignments , in the User's
Guide.
Use a small- to medium-size flat-blade screwdriver to install the 8775 Termination
Unit.
When using a . . .
Hotwire 8600 DSLAM base
chassis
Hotwire 8600 DSLAM
expansion chassis
Hotwire 8800 DSLAM
chassis
An 8775 Termination Unit can be installed, removed, and replaced from a Hotwire
DSLAM chassis without disrupting service to the other cards in the chassis.
NOTE:
When installing the 8775 Termination Unit, you need to remove the filler plate
before proceeding.
Do not discard unused filler plates. Each slot in the chassis must contain a
circuit card or a filler plate. Store all unused filler plates in a safe place. You
may need to use the filler plates to cover open slots in the chassis at a later
time.
March 1998
Install the 8775 Termination Unit in . . .
Slot 2 or 3 (Slot 1 of the Hotwire 8600 DSLAM base
chassis must contain a Management Communications
Controller (MCC) card.)
Slot 1, 2, or 3
Any one of the first 18 slots (i.e., Slot 1 through 18)
3