ANGENIEUX ZOOM LENS
EBI-6209B
applied very lightly moving from the center
surface of the lens towards the edge.
The recommended cleaning agents are the
following:
1. A camel -hair brush.
2. Slightly
moistened Kleenex balls or
dust -free surgical swabs. The moistening
agent should be breath moisture, denatured
alcohol, ether, or acetone.
CLEANING THE GLASS SURFACES
1. Before applying any lens cleaning agent,
first remove all dust particles by using a
syringe.
If this method fails, use a soft
camel -hair brush; however, it is suggested
that
the brush be tapped on the edge of
the Camera pedestal to remove the ac-
cumulated dust particles after each pass
of the brush.
A soft, clean, dust -free cloth can also
be used to remove dust particles. Rotate
the finger when wiping. If you are cleaning
the optical surfaces from right to left, ro-
tate the finger clockwise, and if wiping left
to right, rotate the finger counterclockwise.
Disassembly and Assembly
Refer to Figs. 1 and 2.
ZOOM LENS AND DRIVE ASSEMBLY
1. Remove the Camera Zoom Lens shroud
to expose the Zoom Lens and drive assem-
bly.
2. Open the left-hand door of the Camera
and remove the light shield.
3. Remove the four iris motor wires from
terminal board TB1, located directly below
the servo amplifier power supply. They are
connected as follows on the Type PC -19-A
Camera:
Iris Motor Wires
Connect To TB1-
Red
1
White
2
Orange
3
Black
4
4. Disconnect the plug and cable assembly
on the Type PC -19-D Camera.
5. Loosen the two thumbscrew locking nuts
and move the Zoom Lens and drive assem-
bly forward to its maximum position. The
focus and zoom drive universal couplings
are now exposed.
6. Rotate the flywheel zoom control until
it is in its maximum clockwise position.
7. Rotate the focus control fully clock-
wise
so
that
the zoom drive rod within
the Camera is
in
its maximum position.
If the assembly is being reinstalled on the
Camera, it is necessary to reach into the
interior of the Camera and rotate the zoom
rod manually. The maximum forward posi-
tion is indicated by a mechanical stop.
8. Remove the iris motor wires from
within the Camera (Type PC -19-A only).
9. Loosen, but do not remove, the two
socket set SC No. 8-32 Allen -head set screws
(Fig.
1)
on
the
focus and zoom drives.
Disconnect the hexagons from the univer-
sal joints by pushing the universal joints
back into the Camera.
10. While firmly grasping the zoom lens
and drive assembly, remove the six Allen -
head screws that secure the horseshoe col-
lar to the Camera frame (Type PC -19-A
only).
11. Loosen
the
two
Allen -head socket
screws and pivot C washers under the screw
head. Pull off the lens (Type PC -19-D only).
12. Unscrew the iris wire guide tubing and
tape the iris motor wires to the horseshoe
casting (Type PC -19-A only).
13. Consult your local General Electric
field
representative for shipping instruc-
tions.
14. To reinstall this assembly on the Cam-
era, repeat steps 1 through 12 in reverse
order.
PANHANDLE HOUSING AND SHAFT
1. Open the left- and right-hand Camera
doors.
2. Working from the left side of the Cam-
era, remove the blue preamplifier cover lo-
cated in the bottom portion of the Camera.
3. Remove the ground straps from the
front and rear of the blue yoke assembly.