1 Important safety information

Carefully read the operating instructions all the way through before operating the equipment and retain them
for future reference.
The pictures in these instructions refer to all available versions of the model and may be different from the
actual scope of delivery.
Explanation of symbols and signs used
This is the warning symbol. It warns against possible risk of injury. Follow all instructions which are
marked with this sign to avoid injury or death. The warning symbol always appears in association with
the signal words DANGER, WARNING and CAUTION.
Symbol
Signal word Description
DANGER
Identifies a hazard with a high degree of risk which will cause death or serious
injury if not avoided.
WARNING
Identifies a hazard with a medium degree of risk which could cause death or serious
injury if not avoided.
CAUTION
Identifies a hazard with a low degree of risk which could cause minor or moderate
injury if not avoided.
NOTICE
Identifies a hazard which could result in material damage if not avoided.
Identifies a requirement which needs to be met before an action is taken.
r
1./2./3.
Identifies steps to be taken one after the other by the user.
Identifies the results of an action.
9
Qualification of the operating personnel
The vacuum cleaner must only be used by persons, who have been instructed in its correct usage and explicitly
commissioned with the task of operating it.
The dust extractor is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge. Children should be supervised to ensure that they do
not play with the dust extractor.
Intended use
The vacuum cleaner is suitable for vacuuming up dust and liquids.
Do not use the vacuum cleaner to vacuum up the following:
– Potentially explosive dusts
– Flammable or potentially explosive liquids or absorbent material soaked with these liquids
– Objects which are more than 60 °C hot
Do not run the vacuum cleaner in a potentially explosive environment.
Vacuum cleaners for dust class L are suitable for vacuuming/sucking up dry, non flammable dusts that are haz-
ardous to health with workplace exposure limits >1mg/m³.
4
Vacuum cleaners which are not identified as being suitable for dust class L are only suitable for vacuuming/
sucking up non-hazardous to health dusts.
Only operate the vacuum cleaner under supervision. Do not climb onto or sit on the vacuum cleaner.
The manufacturer does not accept liability for damages caused by misappropriation, inappropriate usage or
incorrect repairs.
Avoid danger from electric shocks
The voltage on the rating plate must match the mains voltage. Only connect the vacuum cleaner to a sufficiently
protected electric socket.
Do not pull the mains connection cable over sharp edges, do not bend it or clamp it. Only replace a damaged
mains connection cable with one meeting the specifications in the Technical Data chapter.
Do not use the vacuum cleaner including accessories in the following cases:
– Mains connection cable or extension cable is defective or showing cracks.
– There is visible damage to the vacuum cleaner, e.g.cracks in the housing.
– If you suspect an invisible defect, e.g. after a fall.
In the following cases, switch the vacuum cleaner off and unplug it from the mains:
– If any foam or liquid is discharged
– In the event of a longer work interruption and after every use
– Before carrying out any maintenance or retooling
When unplugging, only pull on the mains plug and not on the mains connection cable. Never touch the mains
plug with wet hands.
Do not open the vacuum cleaner outdoors in the rain or during a thunderstorm. Always keep the inside of the
lid dry.
Only use the brushes supplied with the vacuum cleaner or those specified in the operating instructions. Using
other brushes can compromise safety. Never allow electrical brushes to come into contact with the mains
connection cable.
Avoid any danger during operation
Only for vacuum cleaners in dust class L: Make sure that the air exchange rate is high enough if the exhaust air
is being fed back into the room (pay attention to applicable national regulations).
Inform operating personnel about the following points before work starts:
– Handling the vacuum cleaner
– Dangers originating from the material to be sucked up
– Safe disposal of the material sucked up
Do not use the blowing function in closed rooms. Only work with a clean suction hose. Do not stir up any dusts
which are hazardous to health. Do not inhale dusts.
When being used in food processing businesses: Immediately clean the vacuum cleaner after use and disinfect
it to avoid microbial contamination.
Avoid any danger during maintenance and repair
Only have repairs carried out by experts. Only use original accessories and spare parts.