WIRING COLOR CODE

Standard Case Wire Color Code
Color Decsription
Ground
Anti-Sweat
Lights
Receptacles
T-Stat/Solenoid 230VAC
T-Stat/Solenoid 115VAC
T-Stat/Solenoid 24VAC
Fan Motors
Blue Condensing Unit
Use Copper Conductors Only
430-01-0338 R101003
IM-H

3. Electrical

Color
Green
Purple
Orange
Yellow
Red/Black
White/Black
This includes (but not limited to) Heaters and Lights.
Red/White
Brown

ELECTRICAL CIRCUIT IDENTIFICATION

Standard lighting for all models will be full length
fluorescent lamps located within the case. The switch
controlling the lights is located at the top right of the case.
FIELD WIRING AND SERIAL PLATE
AMPERAGE
Field Wiring must be sized for component amperes
printed on the serial plate. Actual ampere draw may be
less than specified. Most component amperes are listed
in the "Wiring Diagram" section, but always check the
serial plate.

BALLAST LOCATION

Ballasts are located within the access panel that runs
the length of the top of the case