Power management

The total output of the hob can be lim-
ited to 3.0 kW in order to match to the
requirements of a local network pro-
vider. On hobs with 4 cooking zones,
level 2 of the TwinBooster cannot be set
if Power management is activated (see
"Programming").
38

Safety switch-off

Excessive operating time
The safety switch-off mechanism is
triggered automatically if a cooking
zone is heated for an unusually long
period of time. This time depends on
the power level selected. If it has been
exceeded, the cooking zone switches
off and the residual heat indicator ap-
pears. If you switch the cooking zone
on and off again, it is ready for opera-
tion again.
Safety switch-off if the sensors are
covered
Your hob will switch off automatically if
one or several sensors remain covered
for more than about 13 seconds, for ex-
ample by finger contact, food boiling
over or an object. An  will flash in each
of the cooking zone displays.
Remove the obstruction or clean the
area.  will go out and the hob will be