Reactor Error Code Trouble Shooting Guide
E99: Loss of Communication
Causes:
1) Communications between the display and the motor control board or the temperature
control board has been lost.
When communication is lost, the corresponding display will show E99.
Check all wiring between the display and the corresponding control board.
o Pay close attention to the wire crimping on plug J13 for each display and motor
control boards. And J5/DISPLAY C of temperature control module.
o Swap the J13 plugs from one display to the other
If E99 remains on the same display, replace the Display
If E99 moves to other display then reverse the J13 on motor control with
J5/DISPLAY C of temperature control module to determine if cable or lower
control is the cause.
Rev 2.6 (02/2014)
(Return to Table Of Contents)
Page 42