Reactor Error Code Trouble Shooting Guide
2) E04 on the hose heat display = While the unit was powered on, the Fluid
Temperature Sensor (FTS) lost communication with the temperature control
module.
Check the electrical connections at the temperature control module.
o Looking at plug J1/ SENSOR B on the temperature control module, check and
see if pins 10, 11 & 12 are connected properly.
Pin 12 = purple
Pin 11 = red
Pin 10 = silver (unshielded bare wires)
Check the purple wire cable connections between all hose lengths with FTS
attached...
o Test with an Ohm meter between pins 10 (Silver unshielded bare wire), 11
Red wire, and 12 (Purple wire) of J1/SENSOR B connector disconnected from
the Temperature Control Module.
Check the FTS operation by connecting the FTS directly to the Reactor.
o Locate the FTS.
Rev 2.6 (02/2014)
Pins 11 to 12 approximately 35 ohms per 50' (15.2m) of FTS cable,
plus 10 ohms for the FTS.
Pins 10 to 12 "OL" open loop > 100K ohms.
Unplug the FTS electrical connection.
Plug the Reactor end of the connector directly into the FTS electrical
connector to see if temperature data appears.