Configuring Room Control Unit - Fujitsu Waterstage WOYA060LFCA Installation And Operating Manual

Air to water heat pump, split system
Hide thumbs Also See for Waterstage WOYA060LFCA:
Table of Contents

Advertisement

Air to Water Heat Pump, split system
6 .2

Configuring room control unit

During commissioning, after an initialisation period of
approx. 3 minutes, the user's language must be set:
OK
- Press
- Choose menu "Operator section".
- Choose language.
- Select the language (English, Deutsch, Français,
Italiano, Nederlands, Español, Português, Dansk...)..
" In the case of 2 heating circuits:
- Choose the allocation of the room control unit (room
appliance 1 or 2...) line 40*.
- According to the allocation selected check and, if
necessary, modify the settings for lines 42*, 44*, 48*
Line
Function
I
40
Use as...
This line regulates the use of the room control unit. Depending on how it is used, other settings will be necessary
(lines 42, 44, 48).
42
I
Appliance allocation 1
I
44
Operation HC2 (command HC2)
This function enables you to choose whether you wish the room thermostat (as an option) to act on both zones or just
a single zone.
48
I
Occupancy control switch function
* These parameter lines are only accessible from the room control unit.
Installation and operation manual "1764 - EN"
(wireless)
Setting range
or display
Room appliance 1, 2, P,
User interface 1, 2, P,
Service appliance
Heating circuit 1,
Heating circuit 1 & 2,
Heating circuit 1 & P,
All the heating circuits
Commonly with HC1,
Independent
Without,
Heating circuit 1,
Heating circuit 2,
Common
Setting
Basic
increment
setting
Room
appliance 1
Heating
circuit 1
Commonly
with HC1
- 45 -