Lighting instructions
• Standing pilot
• Gas valve — Robertshaw 7200
FOR YOUR SAFETY READ BEFORE LIGHTING
A. This appliance has a pilot, which must be lighted
by hand. When lighting the pilot, follow these
instructions exactly.
B. Before
, smell all around the appliance
LIGHTING
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle
on the floor. See below.
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone
in your building.
1.
Read the safety information above on this label.
Stop!
2. Set the thermostat to lowest setting.
3. When equipped with
Effikal
place service switch in
4. Turn off all electrical power to the appliance.
5. When equipped with
manually rotate damper blade in direction
Model M35,
of arrow to
position indicated on damper assembly.
Open
6. Depress and move selector arm left
7. When equipped with vent damper, verify damper blade
is in full open position.
Position
indicator
(shown in
OFF
position)
59332
8. Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas,
in the safety information above. If you don't smell
"B"
gas, go to the next step.
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service is to
be performed.
14
If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.

WHAT TO DO IF YOU SMELL GAS

LIGHTING INSTRUCTIONS
vent damper
Model RVGP ,
position.
Hold Damper Open
vent damper
Johnson Controls
to
.
OFF
Selector
arm
Follow
STOP!
TO TURN OFF GAS TO THE APPLIANCE
CGa-25 to CGa-6,
EG-30 to EG-50,
PEG-30 to PEG-50
C. Use only your hand to depress the selector arm. Never use tools. If
the selector arm will not move by hand, don't try to repair it, call a
qualified service technician. Force or attempted repair may result in
a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control,
which has been under water.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
9. Remove access panel located above burners.
10. Find pilot — follow metal tube from gas
control. The pilot is between two burners
behind the access panel.
11. Move selector arm on gas control right
to
position.
SET
12. Hold selector arm in
the pilot with a match. Continue to hold selector arm to
for about one-half (
SET
13. Release selector arm. If pilot does not remain lit, repeat
steps 6 through 13.
If the pilot will not stay lit after several tries, move
selector arm left
technician or gas supplier.
14. Replace access panel.
15. Turn selector arm left
16. Turn on all electric power to the appliance.
17. When equipped with
switch in
Automatic Operation
18. Set thermostat to desired setting.
19. Replace front panel.
3. Remove front panel.
4. Depress and move selector arm left
5. Replace front panel.
position and immediately light
SET
1
/
) minute after the pilot is lit.
2
to
and call your service
OFF
to
.
ON
Effikal
vent damper, place service
position.
to
.
OFF
Part Number 550-110-592/1099