Samsung DV45H Series Service Manual page 38

Clothes dryer
Hide thumbs Also See for DV45H Series:
Table of Contents

Advertisement

■ Centrifugal Switch (Motor)
■ Thermistor
238.23 Ω @
■ GAS MODEL
Radiant Sensor(10RS)
• Resistance value < 1 Ω
• If resistance is infinite, replace Radiant sensor
Igniter(101D)
• Resistance value 40~400 Ω
• If resistance is infinite, replace Igniter
Gas Valve(25M01A)
• Valve 1-2 : Resistance value 1.2K Ω
• Valve 1-3 : Resistance value 0.5K Ω
• Valve 4-5 : Resistance value 1.2K Ω
• If resistance is infinity, replace Valve
Thermostat (60T21 Hi-Limit)230f-50f
• Resistance value < 1 Ω
• If resistance is infinity, replace Thermostat
36 _ Troubleshooting
2.88Ω between
Pin# 3 and 4
3.5Ω between
Pin# 4 and 5
25°C 77
120V
120V 4.5A
120V 60 Hz, 120A
120V 20A (60T2)

Hide quick links: