Download Print this page

Mitsubishi Electric PLP-6EAJ Operation Manual

Package air-conditioner grille, optional part, automatic filter elevation panel
Hide thumbs Also See for PLP-6EAJ:

Advertisement

Quick Links

BH79A276H01
6
MITSUBISHI ELECTRIC Package Air-Conditioner Grille (Optional Part)
MITSUBISHI
Automatic Filter Elevation Panel Operation Manual
.... ELECTRIC
Note
This
EU
symbol mark is for
countries only.
This symbol mark is according to the directive 2006/66/EC Article 20 Information for end-users and Annex II.
Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused.
This symbol means that batteries and accumulators. al their end-of-life, should be disposed of separately from your household waste.
If a chemical symbol is printed beneath the symbol shown above, this chemical symbol means that the battery or accumulator contains a heavy metal at a
certain concentration. This
be indicated as follows:
will
Hg: mercury (0,0005%). Cd: cadmium (0,002%). Pb: lead (0,004%)
In the European Union there are separate collection systems for used batteries and accumulators.
Please, dispose of batteries and accumulators correctly at your local community waste collection/recycling centre.
Please, help us to conserve the environment we live in!
• For correct and safe use, make sure to read this manual thoroughly before using this product.
• In addition to this manual, read the operation manual for the air-conditioner.
• After reading this manual, the users must keep this readily at hand, together with the operation manual for the air-conditioner and
the installation manual for the indoor unit and the grille.
Safety precautions
• Symbols used in this manual are categorized as follows according to the degree of
�Warning
Describes warnings that must be observed to
prevent serious consequences, such as serious
injury or death of the user.
�Caution
Describes precautions that must be observed
to prevent damage to the unit.
Precautions when using
r,
Do not place any objects other
than the filter on the grille.
Do not hang on the lowered
.
-.
1
intake grille.
• Doing so may cause an injury
I[
)I
.
due to a drop or a fall.
-=
Stop the unit before performing
the up/down operation of the
'
intake grille.
1 )
• Otherwise, the intake grille may
drop off and cause an injury or a
failure.
Perform the up/down operation only to clean the
filter and the intake grille.
• Otherwise, it may cause an injury or a failure.
Do not touch or swing the string
(suspender) and the intake grille
during a up/down operation.
• Doing so may cause a collision
of the intake grille or twining of
the string, resulting in an injury or
a failure of the up/down device.
Do not apply downward force on
the intake grille when cleaning
the filter.
• Doing so may cause a failure of
the up/down device.
3. I How to �erform the u�/down o�eration of the intake grille I
( Using Wireless remote controller: )
1) Make sure to turn the air-conditioner "OFF".
2) Press the "Down" button of the wireless remote
controller for Automatic Filter Elevation Panel to
lower the intake grille.
Note1. By initial setting, the intake grille will automatically stop at a lowering distance of 1.6 m from
the ceiling level. If you want to change the initial setting of lowering distance, contact your dealer.
(The distance can be changed to 1.2 m, 2.0 m,2.4 m, 2.8 m, 3.2 m, 3.6 m and 4.0 m. These must
be used only as a guide. You must lower the intake grille yourself to check the exact distance.)
2. When you want to stop the intake grille while it is lowering, press the "STOP" or "UP" button on
the remote controller to stop at that position.
3) Remove the filter or intake grille and clean them.
Note: Refer to the section on how to clean up.
4) Press the "UP" button on the remote controller to put the intake grille in place.
Note1. If the intake grille is not placed in the correct position at a time, the operation is automatically retried. controller for
2. When you want to stop the intake grille while it is rising, press the "STOP" or "DOWN" button on the
remote controller to stop at that position.
( Using the wired remote controller [PAR-3xMAA ("x" represents 2 or later.)] : )
Note1. Raise or lower the intake grilles of the air-conditioners managed by the remote controller. Install the remote
controller in a place where you can observe all the air-conditioners managed with it. Otherwise, the lowering
grille may hit people or objects and cause damage to them.
2. Depending on the connected outdoor unit, operation may not be possible.
[Wired remote controller function]
Function buttons�
The functions of the function buttons change depending on the screen.
Refer to the button function guide that appears at the bottom of the LCD
for the functions they serve on a given screen.
■Main display
( Function button F1 )
Fri
•Main display: Press to chan � e the operation mode.
14:30
•Main menu: Press to move t e cursor down.
( Function button F2 )
26't: �
Cool
Room
Set temp.
Auto
•Main display: Press to decrease the set temperature.
i1 ?A.,..
•Main menu: Press to move the cursor up.
llo
([!i W4
c§ul•&Mittii I)
( Function button F3 )
•Main display: Press to increase the set temperature.
[==i [==i [==i [==i
F1
F2
F3
F4
•Main menu: Press to go to the previous page.
■Main menu
( Function button F4 )
•Main display: Press to change the fan speed.
Main
Main menu
1/3
•Main menu: Press to go to the next page.
►Vane·Louvar·Vent. (Lossnay)
HlghP0W9f
Timer
Weekly timer
Obin disnla:r 5
OU silent mode
wc@nt1Na
( l••s•;,
.JW
l)
t
[==i [==i [==i [==i
F1
F2
F3
F4
[ Operation procedure )
[Procedure
Turn the air-conditioner
1]
"OFF"
1) Select "Maintenance menu" from the main menu with
the [EI] and the [E2:J button, and press the 0 button.
2) Select "Auto descending panel" from the maintenance
menu with the [EI] and the IT2J button, and press
the 9 button.
3) Select " Descending operation" from the auto
descending panel with the [EI] and the IT2] button,
and press the 0 button.
when used improperly:
risk
Symbols used in the figures Indicate the following:
Absolutely not
0
Must be done as instructed
Lt.warning
Do not mix substances other than the designated
refrigerant in the refrigerant cycle when installing
and/or moving the unit.
(S)
• If air or other substances mix in, abnormal high-pressure
will occur in the refrigerant cycle, which may cause explosion.
Mixing other than the specified refrigerant may heavily effect
on the safety guarantee due to the mechanical failure, system
o
malfunction, unit breakdown or accidents.
&Caution
Do not perform up/down operations
consecutively or repeatedly.
Do not leave the intake grille
lowered.
• Doing so may cause an injury or a
(S)
failure of the u /down device.
Do not bend the string, or put objects
such as an edge tool or llt cigarette
on the string.
==-
• Doing so may cause the intake
grille or the filter to drop off due to
string breakage, resulting in an injury.
Keep the wireless remote controller
away from children.
• Otherwise, it may cause an injury.
• Prevent children from accidentally
swallowing batteries.
Before performing the up/down operation of the intake
grille, confirm the safety of the surroundings.
0
• Otherwise, the intake grille may hit people or
objects and cause damage to them.
Warning
Stop the unit before performing the up/down
&
operation of the intake grille.
• Otherwise, the intake grille may drop off and cause an injury
or a failure.
r
Ii
I
bbb
@@0
�I
(MENU button)
ON/OFF button
•Press to bring up the Main menu.
•Press once to turn
ON and twice to OFF.
(RETURN button)
•Press to return to the previous screen.
-( SELECT button )
•Press to save the setting.
and select " Auto descending panel" using the remote controller.
■Maintenance menu
■Auto descending panel
Auto descendin!l eanel
Auto descendin9 eanel
► Auto descending panel
► Descending operation
Manual vane angle
Descending adjustment
3D I-See sensor
Main menu:�
Setting display: v'
-�H]IIZ-1-I1.
•Jl!Jlll-1•I1.
--CJCJ
--CJCJ
F1
F2
F3
F4
F1
0
@@e
@@e
I
1.
Parts names
Grille
String
Wireless remote controller for
Automatic Filter Elevation Panel
How to handle the wireless remote controller (Automatic Filter Elevation Panel)
2.1
(S)
•When using the wireless remote controller, point it towards the sensor from right under the grille.
•The receiver blips to inform you that the signal from the wireless remote controller has been received. Signals can be
received up to approximately 3 meters in a straight line from the controller in an area approximately 30 degrees to the
left and right of the controller. However, illumination such as fluorescent lights and strong light can affect the ability to
receive signals.
•Do not drop the wireless remote controller or subject it to strong shocks.
In addition, do not get the wireless remote controller wet or leave it in a location with high humidity.
•To avoid misplacing the wireless remote controller, keep it in the provided remote controller holder which should be
secured to something such as a wall using the provided screws.
Make sure to place the wireless remote controller back in place after use.
Note: For the details, refer to the installation manual for Automatic Filter Elevation Panel.
( How to set battery )
I(:\
}
•Press and hold the wireless remote controller with a sharp object such as a ballpoint pen in the direction of the
\:::,I
o
arrow (1) and slide toward the direction of the arrow (2) to remove the battery case.
o
•Use the lithium battery (CR2025, 3V).
•Insert the battery into the battery case with the positive side up and install the case back onto the wireless
remote controller.
"
•To remove the battery, reverse the installation procedure.
( 1 )
0
Wireless remote controller for Automatic
Filter Elevation Panel (back side)
I
[Procedure 2] Lower the intake grille
<When used in combination with PLA-EA>
Select "Ref. address", "Unit No." and "Operation"
with the [EI] button.
To lower the intake grille, specify "Ref. address" and
" ' I
"Unit No." of the unit. Select "Down" for "Operation"
with the [E2J and the [El] button, and press
the 9 button.
STOP D
Ref. address : 0 to 15, all in a lump
Unit No. : 1,2,3,4, All
DOWN
...
<When used in combination with PLFY-EM>
Select "M-NET address" and "Operation" with the
[EL] button.
Wireless remote
'--
To lower the intake grille, specify "M-NET address"
of the unit. Select "Down" for "Operation" with the
Automatic Filter
Elevation Panel.
[E2:J and the [IT] button, and press the 0 button.
[Remarks]
If the target unit is unknown, press [E!J. After a
while, the airflow direction of only the displayed
air-conditioner will be switched downward.
(The vane of the untargeted air-conditioners will
all be blocked.)
Press@ as confirmation completed.
___________________
..__
•You cannot stop the operation while the intake grille is lowering.
Note: If you press the@ button while lowering, the intake grille may stop lowering, but it will not stop immediately.
•By the initial setting, the intake grille will automatically stop at the lowering distance of 1.6 m from the ceiling level.
Note: If you want to change the initial setting of lowering distance, refer to the installation manual or contact your dealer.
(The distance can be changed to 1.2 m, 2.0 m, 2.4 m, 2.8 m, 3.2 m, 3.6 m, and 4.0 m. These must be used only as
a guide. Make sure to lower the intake grille yourself to check the exact distance.}
-
I
[Procedure 3] Remove the filter and/or intake grille to clean them.
0
Refer to the section on how to clean up the intake grille and clean the filter and intake grille.
l
I
[Procedure 4] Put the intake grille in the place.
<When used in combination with PLA-EA>
Refer to [Procedure 2] to set "Ref. address" and "Unit No." "Up" and press the 0button.
<When used in combination with PLFY-EM>
Refer to [Procedure 2] to set "M-NET address" "Up" and press the (0button.
•You cannot stop the operation while the intake grille is rising.
Note: If you press the @button while rising, the intake grille may stop rising, but it will not stop immediately.
I
[Procedure 5] Exit the "Auto descending panel".
1) Press @to return to "Maintenance menu".
2) Press@ button on "Maintenance menu".
Complete the ending process and return to "Main menu".
F2
F3
F4
0
13
PLP-6EAJ
(
PLP-6EAJE (with "i-see Sensor")
I
Signal receiver
Sensor for the wireless remote controller of Automatic Filter
Elevation Panel is the same as the sensor for the wireless remote
controller of the air-conditioner. When you want to operate the
air-conditioner using the wireless remote controller, purchase
"Wireless remote controller", which is available separately.
Transmitter section
-
J
O eration section
�,.... - - -_-_-'_'-_-_-
......
UP
Intake grille
STOP
DOWN T
Ballpoint pen
Battery case
(2)
I
<When used in combination with PLA-EA> <When used in combination with PLFY-EM>
Auto descending panel
Ref. address .i
Unit No.
U/2/3/4/AII
Operation
l!'mll I Up
Keep clear, panel descending.
Press Check for Unit No.
---i=l
F1
F2
F3
@@e
\V
Auto descending panel
Ref. address
Unit No.
U/2/3/4/AII
Operation
l!°mll I Up
Panel
stop in 30 sec.
Keep clear, panel descending.
will
i=l i=l i=l i=l
F1
F2
F3
@@G
_,,
I
I
MITSUBISHI ELECTRIC CORPORATION
HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
J
LJ
D
c:::::JC:::::Jbb
0
@@9
Wired remote controller
PAR-3xMAA ("x" represents 2 or later.)
Note: The wired remote controller
can also be used to perform
the up/down operation.
I
,-,Battery
@'
l
Auto descending panel
address ...
► M-NET
Operation
I Up
[!?ll!:m
Keep clear, panel descending.
Check
Press
for Unit No.
Action: v
gg■o-·!i"' • G !'l!! .; � 4 4 1!11 \ l'l!a•Bm?1
---i=l
F4
F1
F2
F3
F4
_
0
0
@@e
'V
(0button
(0button
Auto descending eanel
0
M-NETacttess
1
Operation
[!?ll!m'1 Up
Panel will stop in 30 sec.
Keep dear, panel descending.
i=l i=l i=l i=l
F4
F1
F2
F3
F4
_
0
0
@@G
I
Continued to the
next page

Advertisement

loading

Summary of Contents for Mitsubishi Electric PLP-6EAJ

  • Page 1 This symbol mark is according to the directive 2006/66/EC Article 20 Information for end-users and Annex II. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that batteries and accumulators. al their end-of-life, should be disposed of separately from your household waste.
  • Page 2 ■ ( Using the wi red remote controller (PAR-21 MAA series) : ) 4) If you press the (FI LTER) button when the "Unit No." or "Address No. of indoor unit" is blinking , after a while, the up/down airflow direction of only the displayed air-conditioner will be switched downward . Note: Raise or lower all the intake grilles managed by the remote controller at the same time.

This manual is also suitable for:

Plp-6eaje with i-see sensor