Installing and connecting the refrigerated container
7.2
Operation with AC power
➤ Plug the AC connection cable into the AC power supply connection (fig. 4 2,
page 5).
➤ Connect the refrigerated container to the AC power supply.
7.3
Operation with DC power
A
NOTICE! Risk of damage to the device!
Disconnect the refrigerated container and other electric consumers
from the battery before you connect the battery to a quick charging
device.
Overvoltage can damage the electronics of the device.
For safety reasons, the refrigerated container is equipped with an electronic system
to prevent the polarity being reversed. This protects it against reversed polarity when
connecting to a battery and against short circuiting.
A
NOTICE! Risk of damage to the device!
To avoid voltage drops and loss of performance, keep the cable as short
as possible and avoid joins.
Therefore avoid additional switches, plugs or power strips.
➤ Determine the required cross section of the cable in relation to the cable length
as follows:
12 V
> 3 m
Ø 6 mm²
24 V (with additional module DT-32)
> 6 m
Ø 6 mm²
A
NOTICE! Risk of damage to the device!
Make sure that the polarity is correct.
➤ Before starting up the device for the first time, check whether the operating volt-
age and the battery voltage match (see type plate).
20
3.5 m – 5 m
5.5 m – 8.5 m
Ø 10 mm²
Ø 16 mm²
6.5 m – 10.5 m
Ø 10 mm²
9 m – 13 m
13.5 m – 15 m
Ø 25 mm²
Ø 35 mm²
11 m – 15 m
Ø 16 mm²
TL, FO