Oscilloscope Measuring Functions; Oscilloscope Functions; And Specifications Xxx; Signal Generator - Bosch FSA 760 Original Instructions Manual

Vehicle system analysis
Hide thumbs Also See for FSA 760:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
8.1.5

Oscilloscope measuring functions

Measuring functions
Measuring range
Secondary voltage
5 kV – 50 kV
Primary voltage
20 V – 500 V
Voltage
200 mV – 200 V
5 V – 500 V
AC coupling
200 mV – 5V
Current
2 A
5 A
10 A
20 A
30 A
Current
50 A
100 A
200 A
1000 A
The measuring range is positive or negative depending on the
1)
zero line.
The measuring range is greater than the permissible
2)
measurement voltage
8.1.6

Oscilloscope functions

Function
Input coupling CH1/CH2
Input impedance CH1/CH2
(relative to ground)
Input impedance
CH1/CH2
(galvanically insulated)
Input impedance CH2
(switchover)
Bandwidth CH1
(galvanically insulated)
Bandwidth CH1 (relative to
ground)
Bandwidth CH2 (relative to
ground)
Bandwidth
Measurement lead with voltage
divider
Bandwidth CH2 (differential
measurement)
Bandwidth 1000 A current clamp > 1 kHz
Bandwidth 30 A current clamp
Bandwidth secondary sensor
Bandwidth
Primary connecting cable (UNI 4)
Time ranges (relative to 500
scanning points)
Time ranges (relative to 1
scanning point)
Time basis accuracy
Vertical accuracy
Device without sensors
Vertical resolution
Robert Bosch GmbH
Sensors
1)
Secondary sensor
2)
Primary connecting
2)
cable (UNI 4)
Multi measuring
2)
cable CH1 / CH2
Measurement lead
2)
with voltage divider
Connecting cable
B+/B–
Current clamp 30 A
Current clamp
1000 A
and specifications xxx
Specification
AC/DC
1 MOhm
1 MOhm (5 — 200 V)
10 MOhm (200 mV — 2 V)
4 MOhm
> 5 kHz = 200 mV – 2 V
> 25 kHz = 5 V – 200 V
> 1 MHz = 200 mV – 2 V
> 5 MHz = 5 V – 200 V
> 1 MHz = 200 mV – 2 V
> 5 MHz = 5 V – 200 V
> 500 kHz
> 30 kHZ
> 50 kHz
> 1 MHz
> 100 kHz (20 V)
> 1 MHz (50 V – 500 V)
10 µs – 100 s
20 ns – 200 ms
0,01 %
±2 % of reading
±0,3 % of measuring range
(Offset error for ranges > 1 V)
or ±5 mV
(offset error for ranges 200
mV – 1 V)
10 bit
Technical data | FSA 760 Edition | 29
Function
Memory depth
Scan rate per channel
8.2

Signal generator

Function
Specification
Amplitude
‑10 V – 12 V
(load < 10 mA) to ground
Signal shapes
DC, sinus, triangle, square
Frequency range
1 Hz – 1 kHz
Output current
30 mA – 75 mA
(load‑dependent)
Impedance
ca. 60 Ohm
Symmetry
10 % – 90 % (triangle, square)
Curve generation
Output rate up to 100,000 values/s,
Resolution 8 bit,
Y‑full range adjustable ( bit),
Unipolar / bipolar mode.
Short‑circuit resistance
< 50 V static
to interference voltage
Short‑circuit resistance
< 500 V / 1 ms dynamic
to interference voltage
R
Automatically switched filter and damping elements
for improvement of signal quality.
R
Automatic cutoff at short circuit, interference
voltage detection at start of signal generator.
8.3

Power pack

Function
Input voltage:
Input frequency
Output voltage
Operating temperature
8.4

Noise emissions

< 70 dB(A)
8.5

Dimensions and weights

Function
Dimensions H x B x T:
Weight
8.6

Temperature and humidity

Designation
Operating temperature
Storage temperature
Relative humidity in operation
en
Specification
1 Mega scan values or 50
curves
50 Ms/s
Specification
90 VAC – 264 VAC
47 Hz – 63 Hz
15 V
0 °C – 40 °C
Spezifikation
1785 x 680 x 670 mm
91 kg
Value/Range
5 °C – 40 °C
41 °F – 104 °F
5 °C – 40 °C
41 °F – 104 °F
90 % non‑condensing
1 689 989 298
|
2017-03-08

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsa 760 edition

Table of Contents