Download Print this page

Desa BK Installation Instructions Manual

Blower accessory

Advertisement

Quick Links

Model BK
Manually Controlled
Blower
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS This
appliance is equipped with a three-prong (grounding) plug for your
protection against shock hazard and should be plugged directly into
a properly grounded three-prong receptacle.
(Check your appliance owner's manual for specific applications and additional instructions.)
Parts included with this kit
Part No.
103581-04
104901-01
103650-01
103651-01
11125
101378-01
104902-02
109892-01
109892-02
Tools Required
• Pliers
• Phillips Screwdriver
• Flat Blade Screwdriver
If any of these pieces are missing or damaged, or if the installation instructions for your fireplace or
stove are not included in this manual, contact the dealer where you purchased this kit or DESA Heating
Products at 1-866-672-6040 for referral information.
BK and BKt Blower aCCessory
installation instruCtions
Description
Blower Assembly with Speed Control and 6 foot Cord •
Wire Assembly
Control Knob
Lock Nut
#8 - 1/2" Phillips Head Screw
Thermodisc Switch, 100° Limit
Switch Mounting Bracket
Speed Control Bracket (Stamped Face Models)
Speed Control Bracket (Panel Louver Models)
Model BKt
therMostatiCally
Controlled Blower
Qty
1
1
1
1
1
1
1
1
1

Advertisement

loading

Summary of Contents for Desa BK

  • Page 1 If any of these pieces are missing or damaged, or if the installation instructions for your fireplace or stove are not included in this manual, contact the dealer where you purchased this kit or DESA Heating Products at 1-866-672-6040 for referral information.
  • Page 2 The BK and BKT blowers utilize the same rotary squirrel cage type blower with magnetic attach- WARNING: If there is a du- ment and variable speed control. The BKT also plex electrical outlet installed in includes an additional thermostatically controlled the right side of the bottom of feature for use on some direct-vent models only.
  • Page 3 reMoving louver DIRECT-VENT MODELS There are two different types of direct vent lou- Panel vers: spring latch and bullet-style clip. Spring Remove louver with spring latches by Wood, B-Vent and Vent-Free Latch: simultaneously pulling both top spring latches MODELS toward the center of the appliance until they are For models other than direct vent, remove panel disengaged from the locating holes.
  • Page 4 Route BKT Blower Location Direction Through This Area Blower Installed Blower After Lower Location Panel Removed Thermodisc Magnets Side View Firebox Bottom Side View Firebox Bottom Magnets Figure 6 - Blower Model BKT Figure 5 - Blower Model BK www.desatech.com 108998-01E...
  • Page 5 Model BKt wire MODELS WITh STAMPED PANEL LOUVERS asseMBly Wood, B-Vent and Vent-Free Models Continued 1. Position speed control bracket by inserting 3. Place the blower against the lower rear wall flange of bracket between hearth pan and up- of the firebox outer wrapper with the exhaust per flange of louver opening, then seat bottom port directed upward and the thermodisc end of bracket onto lower flange of louver...
  • Page 6 3. Remove knockout plug from louver panel by Mounting sPeed depressing top and bottom retaining clips (see Control Figure 1, page 2). Continued 4. Position speed control assembly over flange on hearth pan by sliding bracket up between Models With staMped Face the face and the flange, then down until the LOUVERS (B36, VB36 WOOD control shaft is aligned with the opening in the...
  • Page 7 6. Replace all panels and/or brick bottom if (see Figure 2, page 2). previously removed. Turn blower on and check for BK Model: operation. Turn blower off by turning knob fully counterclockwise before continuing. Wiring Diagram Decal 12" in Front of Blower...
  • Page 8 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 Technical Service Department 1-866-672-6040 www.desatech.com 108998-01 Rev. E 108998 01 10/05 NOT A UPC...

This manual is also suitable for: