General safety regulations

Attention! Mounting, installation, commissioning and repair of electronic devices have
!
to be carried out only by qualified electricians. Thus, the current standards for the in-
stallation of door communication system must be observed.
For working on systems with main connection of 230 V alternating voltage, the safety regu-
lations according to DIN VDE 0100 must be observed.
When installing TCS:BUS® systems, the general safety regulations for telecommunication
systems according to VDE 0800 must be observed. Inter alia:
 separated conduit of heavy and low current lines,
 minimum distance of 10 cm in case of a common conduit ,
 use of separators between heavy and low current lines within shared cable ducts,
 use of standard communication lines, e.g. J-Y (St) Y with 0.8 mm diameter ,
 existing lines (modernisation) with deviating cross-sections can be used in compliance
with the loop resistance.
Installation – protective measures
With suitable measures to protect against lightning, it has to be ensured that a voltage
!
of each 32 V DC is not exceeded at the connections.
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88