Introduction
WARNING: Read and understand the safety
chapter before you install the product.
To ground the product
WARNING: The product must be grounded
by a person with good experience and
knowledge in the field of electricity. In some
areas an approved electrician must do the
installation. Obey local regulations.
1. Install a ground rod at a minimum of 24 in. into the
ground.
WARNING: The ground rod must be
made of brass or copper.
Introduction
WARNING: Read and understand the safety
chapter before you use the product.
To fill fuel
Use unleaded gasoline. Do not use gasoline with more
than 10% ethanol and do not use E85 gasoline.
CAUTION: Do not mix gasoline with oil.
1. Stop the engine and let the product become cool.
To stop the product on page 9 .
Refer to
2. Make sure that the product is on level ground and in
an area with good airflow.
3. Remove the fuel tank cap.
4. Carefully fill the fuel tank (A). Fill fuel (B) to the mark
(C). (Fig. 36)
5. Clean the product from fuel spillage.
CAUTION: Fuel spillage is a fire risk and
can cause damage to the environment.
8

Installation

2. Connect a 2.5 mm
terminal on the control panel to a ground rod.
Note: The ground wire and the ground rod are not
supplied with the product.
To connect the product to the electrical
system of a building
WARNING: The product must be grounded
by a person with good experience and
knowledge in the field of electricity. In some
areas an approved electrician must do the
installation. Obey local regulations.
Use a manual transfer switch to connect the product
to an electrical system.
Make sure that you do the procedure in compliance
with all national and local regulations.

Operation

To start the product
1. Disconnect all electrical loads from the receptacles
on the control panel.
2. Make sure that the product is on a level surface.
3. Open the fuel valve.
4. Set the power switch (A) to the ON position. (Fig. 37)
5. Set the choke to the OFF position.
6. Pull the starter rope handle slowly until you feel
resistance.
7. Pull the starter rope handle quickly and with force
until the engine starts.
8. For electric start, do the steps that follow.
a) Push and hold the ON/OFF/START key in the
start position.
b) When the engine starts, move the ON/OFF/
START key to the ON position.
9. Move the choke to ½ choke position.
10. When the engine runs smoothly, set the choke to the
ON position. (Fig. 38)
Note: For G1300P, the ON and OFF positions of the
choke are at the opposite positions.
To connect the electrical loads
WARNING: Do not connect 240 (230) V to
120 (110) V receptacles. Do not connect 3-
phase electrical loads to a 1-phase product.