Altitude Summary Publication Data for PMG Booster Water Heaters
Natural Gas
Altitude:
0-2000
Ft. Above Sea Level
(0-610)
(Meters)
PMG-100
Approved
Input Rate*
105000
Suggested Orifice
Size †
#34DMS #34DMS
GPH Capacity
De-Rate •
1
PMG-200
Approved Input
Rate*
195000
Suggested Orifice
Size †
#35DMS # 3 6 D M S # 3 6 D MS
GPH Capacity
De-rate •
1
Liquid Propane Gas
Altitude:
0-2000
Ft. Above Sea Level
(0-610)
(Meters)
PMG-100 LPG
Approved
Input Rate*
105000
Suggested Orifice
Size †
#50DMS #50DMS
GPH Capacity
De-Rate •
1
PMG-200 LPG
Approved Input
Rate*
195000
Suggested Orifice
Size †
#50DMS #51DMS
GPH Capacity
De-rate •
1
0.61
* This is the maximum allowable btu rate certified by CSA. These are to be verified by the qualified gas installer on site. Check
Heat Value with local Gas Utility
† The first orifice size is the factory built unit. The next sizes are shown at the altitudes where a change is required to allow
pressure adjustments to the approved input rates.
• This is a de-rate multiplier to use when sizing a gas booster for a given application. Take this value and multiply it by the GPH
found on the Hatco sizing chart to ensure it will provide the capacity you need. You can also use this value by dividing it into
your capacity needs and take the resulting adjusted GPH to the sizing chart to select a gas booster.
Form No. PMG100200M-0918
2001-3000 3001-4000
4001-5000
(610-915)
(915-1220) (1220-1525) (1525-1830) (1830-2135) (2135-2440) (2440-2593) (2593-2898) (2898-3203)
103363
101726
100089
#34DMS
#34DMS
0.98
0.97
0.95
171600
163800
156000
# 3 7 D M S
0.88
0.84
0.80
2001-3000 3001-4000
4001-5000
(610-915)
(915-1220) (1220-1525) (1525-1830) (1830-2135) (2135-2440) (2440-2593) (2593-2898) (2898-3203)
102937
100874
98810
#50DMS
#50DMS
0.98
0.96
0.94
171600
163800
156000
#51DMS
#51DMS
0.88
0.84
0.80
5001-6000
6001-7000
7001-8000
98452
96815
95178
#34DMS
#34DMS
#34DMS
0.94
0.92
0.91
148200
140400
132600
# 3 7 DM S
# 3 8 D MS
# 3 9 D MS
0.76
0.72
0.68
5001-6000
6001-7000
7001-8000
96747
94684
92621
#50DMS
#50DMS
#50DMS
0.92
0.90
0.88
148200
140400
132600
#51DMS
# 5 2 D MS
# 5 2 D MS
0.76
0.72
0.68
13
INSTALLATION
8001-8500
8501-9500 9501-10500
94360
90585
86811
#34DMS
#34DMS
#34DMS
0.90
0.86
0.83
128700
123552
118404
# 4 0 DM S
# 4 1 D M S
#42 DMS
0.66
0.63
0.61
8001-8500
8501-9500 9501-10500
91589
87925
84262
#50DMS
#50DMS
#50DMS
0.87
0.84
0.80
128700
123552
118404
#5 2 D M S
# 5 3 D M S
# 53 DMS
0.66
0.63

Hide quick links: