Converting to another gas type
Risk of explosion due to an
incorrect conversion.
If the conversion to another type of
gas is carried out incorrectly, it may
result in gas leakage.
Conversion from one type of gas to
another must only be undertaken by
an approved and registered gas
installer in strict accordance with
current local and national safety and
building regulations. The installer is
responsible for ensuring that the
appliance functions correctly when
installed.
Jet table
The jet markings refer to a ¹/₁₀₀ mm
bore diameter.
Natural gas H
Medium burner
Large burner
Liquid gas
Medium burner
Large burner
Changing the jets
Disconnect the hob from the
electricity supply and turn off the gas
supply.
When converting to another type of
gas, both the main and small jets
need to be changed.
64
Main jet
Small jet
0.94
0.42
1.18
0.54
0.66
0.23
0.81
0.39
Changing the main jets
Remove the pot rest, burner cap
and burner head .
Using an M7 socket spanner,
unscrew the main jet .
Fit the correct jets securely (see jet
table).
Secure the jets against inadvertent
loosening with sealing wax.