Guide to the appliance
KM 7414 FX, KM 7414 FX Glass, KM 7474 FR, KM 7474 FL
Cooking zone
+
1
Pans with a base diameter within the given range may be used.
2
The given range corresponds to the maximum base surface of the pans that may be used.
3
The power given may vary depending on the size and material of the pans used.
22
Size in cm
1
Ø
16–22
–
10–16
–
15–23
19 x 23
15–23
19 x 23
22–23
23 x 39
Max. rating in watts for 230 V
2
Normal
TwinBooster, level 1
TwinBooster, level 2
Normal
TwinBooster, level 1
TwinBooster, level 2
Normal
TwinBooster, level 1
TwinBooster, level 2
Normal
TwinBooster, level 1
TwinBooster, level 2
Normal
TwinBooster, level 1
TwinBooster, level 2
Total
3
2300
3000
3650
1400
1700
2200
2100
3000
3650
2100
3000
3650
3400
4800
7300
7300