Troubleshooting Gas Cotnrol (Sit 822 W/Synetek Electronic Control) - Majestic fireplaces DV580, DV360 Installation And Operating Manual

Direct vent gas fireplace
Hide thumbs Also See for DV580, DV360:
Table of Contents

Advertisement

Normal Operation
ON/OFF Switch Closed?
Safe Start Check On?
0 Sec Purge
Ignition Trial: 30 sec Spark ON
Pilot Valve ON. Has Flame
been Detected within 30 sec?
Spark Off. Main Valve ON.
Pilot Flame Continuously
Monitored
Pilot Flame Sense OK?
ON/OFF Switch Opened?
Pilot and Main Valve OFF?
0 sec Post Purge?
Heating Cycle Complete LED:
OFF
20010667
Troubleshooting the Gas Control System
SIT 822 Valve with Synetek Electronic Control
Operating Diagram
YES
NO
YES
NO
NO
YES
YES
DV360/580 Series Direct Vent Gas Fireplace
Abnormal Operation
5 sec Inter-Trial Delay
LED: Steady Flash?
Lockout: Flame detected out of sequence
Reset by interrupting ON/OFF switch or
power for 10 sec
LED: 5 Flashes?
Reverse power cord polarity
LED: 2 Flashes?
Reset by interrupting ON/OFF
switch for power for 10 sec
Pilot, Valve OFF, Spark OFF
Have three ignition trials been completed?
LED: 3 Flashes?
Lockout: Flame Loss
Reset by interrupting ON/OFF switch or
power for 10 sec
Main Valve OFF, Spark ON
YES
Has flame been detected within 30 sec?
Have three pilot flame losses been
detected?
YES
NO
NO
YES
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents