BFC36 Balance Flue Heat-Circulating Fireplace
Positioning, Safety Strips,
Securing the Fireplace
Slide fireplace into position.
Lift the fireplace front slightly and slide the metal safety
strips under front bottom edge about 1¹⁄₂" (38mm), al-
lowing the remainder to extend in front of firebox. Over-
lap strips at least 1/2" (13mm) to provide a positive joint.
(Flat safety strips are packed with fireplace.)
Safety strips are used to ensure that any combustible
materials in front of the fireplace are protected even
though a non-combustible hearth extension is required.
If fireplace is to be elevated above the floor, a "Z"
shaped metal safety strip must be fabricated and used
to protect combustible surfaces in front of the fireplace.
This "Z" shaped safety strip is not provided but must be
fabricated of metal with each horizontal leg at least 1¹⁄₂"
(38mm) wide and equal in length to the metals strips
provided with the fireplace.
NOTE: Safety strips are not required over non-com-
bustible floors where all supports at the base of the
fireplace are noncombustible.
Four (4) nailing flanges are supplied with the fireplace
(found on the fireplace hearth). To level the box and
secure it firmly in place, remove the nailing flanges from
the hearth and install at the sides of the fireplace as
shown in Figure 13.
10
(Fig. 12)
1¹⁄₂"
(38mm)
Fig. 12 Safety strip installation.
Fig. 13 Fasten fireplace in position.
Metal Safety Strips
(1,2 or 3 pcs.)
"Z" Safety
Fire-
Strip
place
(not sup-
plied)
¹⁄₂" (13mm)
Plat-
Min. Overlap
form
Hearth Ext.
WF557
BR
11/10/97
FPC549a
BFC
Nail flange/standoff
circulating models
8/21/00 djt
FP557b
Nail Top
Standoffs
Nail Side-
Nailing
Flanges
FPC549a
7412647