Built-in ovens
Underbench oven
Your underbench oven looks best when the control panel is directly
under the benchtop. An upper infill panel may be added if the cooktop
placed above the benchtop is too deep. Refer to cooktop installation
instructions for required clearance between cooktop and oven.
IMPORTANT!
Note: Dimension'D'*
A requirement for all EVEPxxxx pyrolytic clean ovens and all Duo
ovens – for proper ventilation there MUST be a gap at the bottom
rear of the cabinet. This can be a full width opening 20mm deep.
Refer to dimension "D" in relevant diagram.
Power point connection for the oven must be accessible with the
appliance fully installed. If the supply cord is damaged it must be
replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Cut-out dimensions
Type of fit
A (width)
Flush fit (mm)
600
Proud fit (mm)
568
Double oven cut-out dimensions
Type of fit
A (width)
Flush fit (mm)
600
Proud fit (mm)
568
650mm
min.
B (height)
C (depth)
600
581 min.
590
560 min.
561mm
mounting
holes
582mm.
Fit black
596mm
screws
provided.
B (height)
C (depth)
1086
581 min.
1078
560 min.
561mm
mounting
holes 582mm.
Fit black
screws
provided
mounting holes.
Fit black screws with
plastic spacers provided
Pyrolytic underbench cut-out dimensions
Type of fit
A (width)
Flush fit (mm)
600
A
B
D*
C
Duo oven cut-out dimensions
Type of fit
A (width)
Flush fit (mm)
600
D
650mm
min.
Technical specifications
dimension
Model
(HxWxD)mm
EVE602
597 x 596 x 568 230-240V/50Hz
EVE614
597 x 596 x 568 230-240V/50Hz
EVE616
597 x 596 x 568 230-240V/50Hz
EVEP614
597 x 596 x 572 230-240V/50Hz
EVEP616
597 x 596 x 572 230-240V/50Hz
EVEP618
597 x 596 x 572 230-240V/50Hz
EVE626
890 x 596 x 568 230-240V/50Hz
EVEP626
890 x 596 x 572 230-240V/50Hz
EVE636
1083 x 596 x 568 230-240V/50Hz
Hard wiring details
1. Remove terminal cover plate
from rear panel of appliance.
2. Fit wires through hole in
cover plate and make
connections to terminals.
3. Engage wires into plastic clip.
Secure plastic clip with two
long silver screws (supplied in
separate bag).
4. Replace cover plate onto
rear panel.
B (height)
C (depth)
600
581 min.
561mm
mounting
holes
582mm
596mm
B (height)
C (depth)
893
581 min.
561mm
mounting holes
582mm. Fit black
screws provided
mounting holes.
Fit black screws with
plastic spacers provided
max
electrical
min fuse
power
connection
rating
rating
16A
3.1kW
16A
3.1kW
16A
3.1kW
16A
3.1kW
16A
3.1kW
16A
3.1kW
25A
5.3kW
25A
5.3kW
32A
6.2kW
D*
20
D*
20
max
current
rating
12.9A
12.9A
12.9A
12.9A
12.9A
12.9A
22.1A
22.1A
25.8A
Plastic clips
Plastic clip
securing points

Advertisement