Vector Power City VEC029AC Owner's Manual & Warranty

Vector Power City VEC029AC Owner's Manual & Warranty

Multi-function ac/dc jumpstart system

Advertisement

VEC029AC
POWER
MULTI-FUNCTION
AC/DC JUMPSTART SYSTEM
VEHICLE JUMPSTARTER • 200 WATT INVERTER
260 PSI AIR COMPRESSOR • WORKLIGHT/LANTERN
OWNER'S MANUAL
& WARRANTY INFORMATION
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION,
MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USE, READ AND
UNDERSTAND ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT LABELS,
PLUS YOUR VEHICLE'S BATTERY MANUFACTURER GUIDELINES. FAILURE TO DO SO COULD
RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE.
4140 SW 28TH WAY, FT. LAUDERDALE, FL 33312
TEL 954-584-4446 • FAX 954-584-5556
1

Advertisement

Table of Contents
loading

Summary of Contents for Vector Power City VEC029AC

  • Page 1: Warranty Information

    VEC029AC POWER ™ MULTI-FUNCTION AC/DC JUMPSTART SYSTEM VEHICLE JUMPSTARTER • 200 WATT INVERTER 260 PSI AIR COMPRESSOR • WORKLIGHT/LANTERN OWNER’S MANUAL & WARRANTY INFORMATION THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USE, READ AND UNDERSTAND ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT LABELS, PLUS YOUR VEHICLE’S BATTERY MANUFACTURER GUIDELINES.
  • Page 2 DO NOT clamp directly to positive battery terminal or moving part. • Replace worn or defective parts immediately - contact Vector Technical Support Department at (954) 584-4446. • Skin: if battery acid comes in contact with skin, rinse immediately with water, then wash thoroughly with soap and water.
  • Page 3: Table Of Contents

    1. INTRODUCTION ... 1.1 General Discription ... 4 1.2 Key Features ... 5 1.3 Use Power City to ... 5 1.4 Storage Location ... 6 2. USE AS A JUMPSTART SYSTEM ... 2.1 Jumpstart Warnings ... 5 3. USE AS A 12 VOLT DC PORTABLE POWER SUPPLY ... 4.
  • Page 4: Introduction

    Power City is also ideal to power 12 volt DC cordless, portable, rechargeable appliances with ratings up to 23 amperes. For information about Vector appliances, contact Vector Customer Sup- port for the location of the nearest retailer.
  • Page 5: Key Features

    FIGURE 2 1. NEGATIVE (BLACK) CLAMP 2. AIR COMPRESSOR ON/OFF SWITCH 3. AC RECHARGE PORT 4. POSITIVE (RED) CLAMP 5. AIR COMPRESSOR PRESSURE GAUGE 6. 110 VOLT AC CHARGER KEY FEATURES • ON/OFF safety power switch (no key required, no key to get lost!) •...
  • Page 6: Storage Location

    STORAGE LOCATIONS Figure 3 shows all removable parts and their locations. Note the location of the storage channels for the jumper cables and compressor hose and nozzle. Two cables are supplied with Power City and they are the Inverter Power Cable with attached Lantern Extension cord and the DC Recharge Cable.
  • Page 7: Use As A 12 Volt Dc Portable Power Supply

    USE AS A 12 VOLT DC PORTABLE POWER SUPPLY WARNING: NEVER INSERT A CIGARETTE LIGHTER IN POWER CITY’S ACCESSORY SOCKET. 1. Lift up the cover of one of the12 volt DC Accessory Sockets. 2. Insert the 12 VOLT DC plug from the appliance into the Accessory Socket. 3.
  • Page 8: Principles Of Operations

    PRINCIPLES OF OPERATION The Power Inverter converts power in two stages. The first stage is a DC-to-DC conversion process that raises the low voltage DC at the inverter input to 145 volts DC. The second stage is the actual inverter stage that converts the high voltage DC into 110 volts, 60 Hz AC, Modified Sine Wave (MSW).
  • Page 9: 4.3.1 Procedure For Connecting Inverter To Remote Dc Source

    If the inverter is connected to the incorrect polarity, the fuse will blow. If the unit does not function after replacement of the fuse, the unit must be returned to Vector for repair. Repairs for this type of damage are not covered by warranty.
  • Page 10: Placement Of The Power Inverter

    DO NOT CONNECT TO AC DISTRIBUTION WIRING: the inverter is engineered to be connected directly to standard electrical and electronic equipment in the manner described above. Do not direct wire the power inverter to household or RV ac distribution wiring. Do not connect the power inverter to any AC load circuit in which the neutral conductor is connected to ground (earth) or to the negative of the DC (battery) source.
  • Page 11: Inverter Fuse Replacement

    8. If fuse is good the green LED will light. 9. Check for proper operation by powering a 110 VAC appliance. If there is still a problem, call Vector Technical Support at 954-584-4446. NOTE: If the Main Unit battery is discharged, the Inverter may also be quickly checked by connecting the Inverter Power Cable to the inverter's power pins and plugging the DC Plug into a known to be operating 12 volt DC accessory socket.
  • Page 12: Tire Inflation Or Products With A Valve Stem

    TIRE INFLATION OR PRODUCTS WITH A VALVE STEM 1. Place connector (chuck) on valve stem. 2. Push connector toward valve stem and close thumb latch. 3. Make sure connector is pushed on to valve stem as far as possible before closing thumb latch. 4.
  • Page 13: Lantern Operation Detached From Main Unit

    LANTERN OPERATION DETATCHED FROM MAIN UNIT The Lantern may be removed for use away from the Main Unit by first sliding the top latch back and then lifting the Lantern as shown in Figure 8. FIGURE 8 LANTERN LATCH A barrel connector near the spring contacts on the back of the Lantern accepts either the AC Recharge or DC Inverter Power Cable’s Lantern Extension cord.
  • Page 14: Lamp Replacement

    All lead-acid batteries suffer from self-discharge over time and more rapidly when they are at higher temperatures. Therefore, these types of batteries need periodic charging to replace energy lost through self-discharge. When Power City is not in use Vector recommends that the batteries be recharged at least every 60 days.
  • Page 15: Ac Recharging

    AC RECHARGE AC Recharge requires the use of the supplied AC/DC Adapter. The adapter must be powered from 110 volt AC, 60 Hz North American standard household AC receptacles. The Battery Status Display will automatically activate during AC recharge. As recharge progresses, the red LEDs will light one by one.
  • Page 16: Alternate Dc Recharge

    WARNINGS: Other than a fuse in the inverter and a lamp in the lantern, there are no user serviceable parts inside. DO NOT operate unit if there is any evidence of damage. The product must be returned to vector for testing and repair. Replace any damaged cables immediately before further use.
  • Page 17: Specifications

    SPECIFICATIONS: Jump Start Clamps ... 400 Amps - Heavy Duty Copper Jumper Cables ... #5AWG Welding Cable Peak Amps ... 1800 Instant Amps ... 400 Main Battery ... 12 Volt, 19 Amp Hour, Sealed Lead-Acid Lantern Lamp ...11 Watt Flourescent U Tube Dual Accessory Socket Protection ...
  • Page 18: Warranties

    All Vector Manufacturing, Ltd. products are warranted to the original purchaser only for 120 days from the date of purchase, to be free of defects in materials and workmanship. Vector Manufacturing, Ltd. disclaims any liability for consequential damages. In no event will Vec- tor Manufacturing, Ltd.
  • Page 19 All Vector Manufacturing, Ltd. products must be registered within (10) days of purchase to activate this warranty. Mail the completed registration form, along with a copy of the original sales receipt, and a check or money order for US$45.00 made payable to Vector Manufacturing, Ltd., to: ATTN.: CUSTOMER SERVICE / VECTOR MANUFACTURING, Ltd.
  • Page 20 © 2000 VECTOR MANUFACTURING, Ltd. FT. LAUDERDALE, FL 33312 MADE IN CHINA...