Vector START-IT VEC078 Owner's Manual & Warranty

Vector START-IT VEC078 Owner's Manual & Warranty

Automatic battery charger

Advertisement

Quick Links

AUTOMATIC BATTERY CHARGER
OWNER'S MANUAL & WARRANTY INFORMATION
12 VOLT 2/12 AMPERE WITH 100 / AMPERE START ASSIST
AND MANUAL 6 VOLT 15 AMPERE BATTERY CHARGE
1.
WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE
EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS OF
UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER, YOU READ THIS
MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY.
2.
To reduce risk of battery explosion, follow these instructions and those published by the battery
manufacturer and manufacturer of any equipment you intend to use in vicinity of battery.
GENERAL BATTERY SAFETY:
Review cautionary marking on these products and on engine.
1. Use charger for charging a LEAD-ACID battery only. It is not intended to supply power to a low voltage
electrical system other than in an automotive application. Do not use battery charger for charging dry-
cell batteries that are commonly used with home and portable appliances. These batteries may burst and
cause injury to persons and damage to property.
2. Use of an attachment not recommended or sold by the battery charger manufacturer may result in a risk
of fire, electric shock, or injury to persons.
3. To reduce risk of damage to electric plug and cord, pull by plug rather than cord when disconnecting
charger.
4. An extension cord should not be used unless absolutely necessary. Use of an improper extension cord
could result in a risk of fire and electric shock. If extension cord must be used, make sure:
a. That pins on plug of extension cord are the same number, size, and shape as those
of plug on charger.
b. That extension cord is properly wired and in good electrical condition; and
c. That wire size is AWG #16 (16 gauge) for up to 25 feet; AWG #12 (12 gauge) for up to 50 feet;
AWG # 10 (10 gauge) for up to 100 feet; and AWG # 8 (8 gauge) for up to 150 feet.
5. Do not operate charger with damaged cord or plug - replace the cord or plug immediately.
6. Do not operate charger if it has received a sharp blow, been dropped, or otherwise damaged in any
way; take it to a qualified serviceman.
7. Do not disassemble charger; take it to a qualified serviceman when service or repair is required.
Incorrect reassembly may result in a risk of electric shock or fire.
8. To reduce risk of electric shock, unplug charger from outlet before attempting any maintenance or
cleaning. Turning off controls will not reduce this risk.
9. Do not expose charger to rain or snow.
10. Never charge a frozen battery
• IMPORTANT SAFETY INSTRUCTIONS •
This manual contains important safety and operating instructions for battery charger Model VEC078
Tel: (954) 584-4446 Fax: (954) 584-5556 Toll Free: (866) 584-5504
START-IT
SAVE THESE INSTRUCTIONS
4140 S.W. 28th Way, Ft. Lauderdale, FL 33312
www.vectormfg.com
-
VEC078

Advertisement

Table of Contents
loading

Summary of Contents for Vector START-IT VEC078

  • Page 1: Important Safety Instructions

    AUTOMATIC BATTERY CHARGER OWNER’S MANUAL & WARRANTY INFORMATION 12 VOLT 2/12 AMPERE WITH 100 / AMPERE START ASSIST AND MANUAL 6 VOLT 15 AMPERE BATTERY CHARGE WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER, YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY.
  • Page 3 VECTOR “GOLD SEAL” 2/4 YEAR LIMITED WARRANTY PROGRAM This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of Vector Manufacturing, Ltd., regarding this product. There is no other warranty, other than those described herein.
  • Page 4: Appendix A - Charging Times

    APPENDIX A - CHARGING TIMES To calculate the approximate charging time required to fully charge a battery, it is necessary to determine the specific gravity (or, percent of battery charge) using a hydrometer. Use this technique, if battery vent caps can be removed. Check each cell. If there is one cell with a very low specific gravity compared to the other cells, there is probably a shorted cell in the battery.
  • Page 5 PERSONAL PRECAUTIONS AND SAFETY 1. Someone should be within range of your voice or close enough to come to your aid when you work near a lead-acid battery. 2. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes. 3.
  • Page 6: Preparing To Charge

    PREPARING TO CHARGE 1. Determine voltage of battery by referring to car owner’s manual and make sure that output voltage selector switch is set at correct voltage. 2. If it is necessary to remove battery from vehicle to charge, or to clean terminals, always remove grounded terminal from battery first.
  • Page 7 • Keep the charger cords loosely coiled during storage to prevent damage to the cords. Do not use the charger if cords or clamps have been damaged in any way - call Vector Technical Support Department at (954) 584-4446 or toll free at (866)-584-5504 for details on replacing cords and clamps.
  • Page 8: Charging If Battery Is Outside Of Vehicle

    NOTE: If there is any problem connecting the charger clamps to the battery terminals, contact the Vector Technical Support Department at (954) 584-4446 or toll free at (866)-584-5504 for assistance.
  • Page 9: Introduction And Features

    See operating instructions for length of charge information. INTRODUCTION AND FEATURES Thank you for selecting the Vector(r) Model VEC078 2/15/100 Automatic Battery Charger. With proper care and use, it will give you years of dependable service. Please read all safety warnings and cautions, and this entire User’s Manual, before using this device.
  • Page 10: Charger Controls

    CHARGER CONTROLS Charger controls are located on the front panel. Understand control use before operating charger. CHARGE RATE SELECTOR SWITCH • The Charge Rate Selector switch on the front panel of the charger (Figure 3) offers two 12 volt and one 6 volt charge rates for charging various types of batteries and an Engine Start position to assist starting engines.
  • Page 11: Circuit Breaker

    higher, so it needs to rest after charging to measure actual state of charge. Below the Ammmeter is an incorrect polarity indicator that lights when incorrect polarity is sensed. It is marked REVERSE. See figure 6a. It indicates that the charger to battery connection is reversed and it must be reconected before charging can begin.

Table of Contents