Mantel Clearances; Floor Clearances - Vanguard Flame-Max VYS18PWA Operating And Installation Manual

Unvented (vent-free) propane/lp gas log heater
Table of Contents

Advertisement

INSTALLATION
Continued

MANTEL CLEARANCES

In addition to meeting noncombustible mate-
rial clearances, you must also meet required
clearances between fireplace opening and
mantel shelf. If you do not meet the clear-
ances listed below, you will need a hood.
Determining Minimum Mantel
Clearance
If you meet minimum clearance between
mantel shelf and top of fireplace opening, a
hood is not required (see Figure 6).
Determining Minimum Mantel
Clearance When using a Hood
If minimum clearances in Figure 6 are not
met, you must have a hood. When using a
hood there are still certain minimum mantel
clearances required. Follow minimum clear-
ances shown in Figure 7 when using hood.
NOTICE: Surface temperatures of
adjacent walls and mantels be-
come hot during operation. Walls
and mantels above the firebox
may become hot to the touch. If
installed properly, these tempera-
tures meet the requirement of the
national product standard. Fol-
low all minimum clearances
shown in this manual.
NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the
following:
• operate the logs only with the
flue damper open
• raise the mantel to an accept-
able height
• remove the mantel

FLOOR CLEARANCES

A. If installing appliance on the floor level,
you must maintain the minimum dis-
tance of 14" to combustibles (see Fig-
ure 8).
B. If combustible materials are less than
14" to the fireplace, you must install
appliance at least 5" above the combus-
tible flooring (see Figure 9).
105190
Minimum Non-
Combustible
Material
Minimum Non-
Combustible
Material Height
Figure 6 - Minimum Mantel Clearances Without Using Hood
Minimum Non-
Combustible
Material
Figure 7 - Minimum Mantel Clearances When Using Hood
14"
Min.
Noncombustible Material
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
9
OWNER'S MANUAL
Mantel Shelf
10"
8"
6"
1 /2
2
"
(A)
12"
18"
20"
22"
8"
8"
14"
17"
Distances to
Underside of
Mantel
Mantel Shelf
12"
10"
8"
6"
1 /2
2
"
8"
12"
15"
Min.
Hood
Hood
Distances to
(GA6050, GA6052,
(GA6050, GA6052)
Underside of
or GA6053)
Mantel
Combustible
Material
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
Underside of
Mantel Shelf
All minimum
distances are
in inches
Log Set
Log Set
24"
24"/30"/36" Models
24" and 30" Models
20"
18" Model
Top of Fireplace
Opening
Underside of
Mantel Shelf
All minimum
distances are
in inches
18"
20"
Top of Fireplace
Opening
Hearth
Hearth
Combustible
Combustible
Material
Material
5"
5"
Min.
Min.
Continued

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flame-max vys24pwaFlame-max vys30pwa

Table of Contents