Error Codes Summary - Qume QVT 101 Maintenance Manual

Table of Contents

Advertisement

TROUBLESHOOTING
ERROR CODES SUMMARY
As part of the terminal's power on sequence, it performs an internal self-
test, and signals that it has successfully completed this test by sounding the
audible alarm.
However, if a non-fatal error is detected, an error code will
be displayed'on the screen. For example, if the letter "0" is displayed, this
signifies that a fault has been isolated to the Power/Logic PCB (i.e. IC
Ul8). The following table lists all possible error codes.
Table 1-1.
Error Codes
Su ....
ry
ERROR CODE
CORRECTIVE ACTION
A
Replace UlO, or the Power/Logic PCB.
B
Replace U8, U9, or the Power/Logic PCB.
C
Replace U8, U9, UlO, or the Power/Logic PCB.
o
Replace Ul8, or the Power/Logic PCB.
E
Replace UlO and U18, or the Power/Logic PCB.
F
Replace U8, U9 and U18, or the Power/Logie PCB.
G
Replace U8, U9, U10 and U18, or the Power/Logic PCB.
H
Replace the keyboard.
I
Replace U10, or the Power/Logic PCB, and the keyboard.
J
Replace U8 and U9, or the Power/Logic PCB, and the keyboard.
K
Replace U8, U9 and UlO, or the Power/Logic PCB, and the keyboard.
L
Replace U18, or the Power/Logic PCB and the keyboard.
M
Replace U10 and U18, or the Power/Logic PCB and the keyboard.
N
Replace U8, U9 and U18, or the Power/Logic PCB and the keyboard.
o
Replace U8, U9, UlO and U18, or the Power/Logic PCB and the
keyboard.
Note:
U8, U9, UlO and U18 are located on the Power/Logic PCB.
1-10