Monogram ZIR300NPKII Installation Instructions Manual

Monogram ZIR300NPKII Installation Instructions Manual

18” and 24”built-in column freezers 24” and 30” built-in column refrigerators
Table of Contents

Advertisement

Quick Links

Installation
Instructions
18" and 24"Built-In Column
Freezers
24" and 30" Built-In Column
Refrigerators

Advertisement

Table of Contents
loading

Summary of Contents for Monogram ZIR300NPKII

  • Page 1 Installation Instructions 18” and 24”Built-In Column Freezers 24” and 30” Built-In Column Refrigerators...
  • Page 2: Safety

    Keep fingers out of the “pinch point” areas; clearances between the doors and between the doors and cabinet are necessarily small. Be careful closing doors when children are in the area. For Monogram local service in your area, call 1.800.444.1845 or visit monogram.com. For Monogram service in Canada, call 1.800.561.3344 For Monogram Parts and Accessories, call 1.800.444.1845 or visit monogram.com.
  • Page 3: Table Of Contents

    Contents Safety Instructions for Single Integrated Installation Design Guide The Installation Space Dimensions and Clearances Tools, Hardware, Materials Accessories/Kits Grounding the Unit Flooring Instructions for Dual Integrated Installation Step 1. Remove Packaging The Installation Space Step 2. Install Water Line Tools, Hardware, Materials Step 3.
  • Page 4: Design Guide

    Design Guide DIMENSIONS AND CLEARANCES Dimensions in parentheses are in centimeters. Overall Dimensions TOP VIEWS DOOR OPEN 90 DOOR OPEN 115 FRONT VIEW SIDE VIEW Dimensions 18” Models 24” Models 30” Models Overall Width - Front 17-1/2” 23-1/2” 29-1/2” (44.5 cm) (59.7 cm) (74.9 cm) Overall Width - Rear...
  • Page 5: Accessories/Kits

    Design Guide door reversal instructions and two options for door panel installation. Instructions for Dual Integrated Installation New construction installation with 25” deep openings Instructions for Dual Retro Installation Existing construction installation (existing cutouts) with 24” deep openings that are 41-1/2” or 47-1/2” wide Instructions for Single Integrated Installation New construction installation with 25”...
  • Page 6: Instructions For Dual Integrated Installation

    Instructions for Dual Integrated Installation New construction installation with 25” deep openings 31-49133-1...
  • Page 7 Design Guide - Dual Integrated Installation DUAL INTEGRATED INSTALLATION SPACE Dimensions in parentheses are in centimeters. 18” Integrated Freezer 24” Integrated Freezer 24” Integrated Refrigerator 24” Integrated Refrigerator 25" 25" 41 1/2" (63.5) 47 1/2" (63.5) (120.7) (105.4) 3 1/2" 3 1/2"...
  • Page 8: Tools, Hardware, Materials

    Installation Instructions - Dual Integrated Installation REFRIGERATOR/FREEZER LOCATION GROUNDING THE UNIT Do not install the refrigerator/freezer where the tem- WARNING perature will go below 55°F (13°C). It will not run Electrical Shock often enough to maintain proper temperatures. Hazard. Failure to follow these instructions can Do not install the refrigerator/freezer where result in death, fire, or electrical shock.
  • Page 9: Step 1 Remove Packaging

    Installation Instructions - Dual Integrated Installation STEP 1 REMOVE PACKAGING STEP 2 INSTALL WATER LINE Connect to potable water supply WARNING WARNING Tip Over Hazard. This only. appliance is top heavy. Use extreme caution with moving to prevent tipping over which could result in A cold water supply is required for automatic death or serious injury.
  • Page 10: Step 3 Preparing Unit For Installation

    Installation Instructions - Dual Integrated Installation STEP 3 PREPARING UNIT FOR INSTALLATION Place the right hand unit in front of the installation Install adhesive heater on the outside of the unit to opening in a way that the unit is in front of the intended the left side of the case.
  • Page 11: Step 4 Install Anti-Tip Bracket

    Installation Instructions - Dual Integrated Installation STEP 4 INSTALL ANTI-TIP BRACKET STEP 3 PREPARING UNIT FOR INSTALLATION (Cont.) WARNING Tip Over Hazard. WARNING Electrical Shock These appliances are top heavy, especially with Hazard. any doors open, and must be secured to prevent To avoid the risk of electric shock, make tipping forward which could result in death or seri- sure the power cord is not plugged into the wall...
  • Page 12: Step 5 Joining Dual Installed Units

    Installation Instructions - Dual Integrated Installation STEP 4 INSTALLING ANTI-TIP STEP 5 JOINING DUAL INSTALLED BRACKET (Cont.) UNITS Mount the anti-tip bracket centered about the marks Place the left hand unit in front of the opening. and flush to the floor as shown. Mark 3 holes for wall Install top unification bracket between the 2 units by mounting or 4 holes for floor mounting.
  • Page 13: Step 6 Connecting Water Supply

    Installation Instructions - Dual Integrated Installation STEP 6 CONNECTING WATER SUPPLY Copper Tubing: Connect to potable water supply WARNING only. Slip a 1/4” nut and ferrule (provided) over both ends of the copper tubing. Insert the tube into the union fitting on the unit and tighten the nut to the union.
  • Page 14: Step 7 Inserting/Securing Into Cabinet Surround

    Installation Instructions - Dual Integrated Installation STEP 7 INSERTING/SECURING INTO CABINET SURROUND Plug both units into the outlet in the wall. As you walk the unit back, pull the anti-tip strap tight. Secure the strap in the front of the unit. This process should be completed for each unit.
  • Page 15: Step 8 Level Unit

    Installation Instructions - Dual Integrated Installation STEP 8 LEVEL UNIT STEP 9 FINAL EXTERNAL UNIT PREPARATION All models have 4-point leveling. The front is supported by leveling legs; the rear is supported by adjustable FOR FLUSH INSTALLATION: Make sure front wheels.
  • Page 16: Step 10 Internal Unit Preparation

    Installation Instructions - Dual Integrated Installation STEP 9 FINAL EXTERNAL UNIT STEP 11 START ICEMAKER PREPARATION (Cont.) (freezer models) Install front mullion and access cover trims between the 2 units. Open the doors and push the flexible CAUTION Avoid contact with the moving parts “dart”...
  • Page 17: Step 12 Install Autofill Pitcher Assembly

    Installation Instructions - Dual Integrated Installation STEP 12 INSTALL AUTOFILL PITCHER ASSEMBLY (Some Refrigerator Models) Locate the AutoFill pitcher cover on the left side of the Conceal wires and tubing inside the wall compartment refrigerator’s interior. Remove T20 Torx screw holding and place the AutoFill wall assembly onto the forward the cover in place towards the rear of the cover.
  • Page 18: Instructions For Dual Retro-Fit Installation

    Instructions for Dual Retro-Fit Installation Existing construction installation with 24” deep openings that are 41-1/2” or 47-1/2” wide 31-49133-1...
  • Page 19: The Installation Space

    Design Guide - Dual Retro-Fit Installation DUAL RETRO-FIT INSTALLATION SPACE Dimensions in parentheses are in centimeters. 24" 47 1/2" (61.0) (120.7) 20" (50.8) 6" (15.2) 5" (12.7) *83 1/2" min *84 1/2" max 75" (212.1-214.6) (190.5 ) *Trim will overlap From floor additional 7/16 "...
  • Page 20: Tools, Hardware, Materials

    Installation Instructions - Dual Retro-Fit Installation REFRIGERATOR/FREEZER LOCATION GROUNDING THE UNIT Do not install the refrigerator/freezer where the tem- WARNING perature will go below 55°F (13°C). It will not run Electrical Shock often enough to maintain proper temperatures. Hazard. Failure to follow these instructions can Do not install the refrigerator/freezer where result in death, fire, or electrical shock.
  • Page 21: Step 1 Remove Packaging

    Installation Instructions - Dual Retro-Fit Installation STEP 2 INSTALL WATER LINE STEP 1 REMOVE PACKAGING Connect to potable water supply WARNING WARNING Tip Over Hazard. only. This appliance is top heavy. Use extreme caution with A cold water supply is required for automatic icemaker moving to prevent tipping over which could result in and AutoFill pitcher operation.
  • Page 22: Step 3. Preparing Unit For Installation

    Installation Instructions - Dual Retro-Fit Installation STEP 2 INSTALL WATER LINE STEP 3 PREPARING UNIT FOR (Cont.) INSTALLATION (Cont.) Install adhesive heater on the outside of the unit to NOTE: The only GE Appliances approved plastic tubing the left side of the case. Install heater 2” below the top is supplied in the SmartConnect Refrigerator Tubing ™...
  • Page 23: Step 4 Install Anti-Tip Bracket

    Installation Instructions - Dual Retro-Fit Installation STEP 4 INSTALL ANTI-TIP BRACKET STEP 3 PREPARING UNIT FOR INSTALLATION (Cont.) WARNING Tip Over Hazard. WARNING Electrical Shock These appliances are top heavy, especially with any doors open, and must be secured to prevent Hazard.
  • Page 24: Step 5 Joining Dual Installed Units

    Installation Instructions - Dual Retro-Fit Installation STEP 4 INSTALL ANTI-TIP BRACKET STEP 5 JOINING DUAL INSTALLED (Cont.) UNITS STEEL MOUNTING: Predrill with a 1/2” drill bit, insert Place the left hand unit in front of the opening. toggle, then install bolts with a 7/16” driver. Install top unification bracket between the 2 units by The bracket must be screwed to either the FLOOR or sliding in place over the two shoulder bolts.
  • Page 25 Installation Instructions - Dual Retro-Fit Installation STEP 5 JOINING DUAL INSTALLED UNITS (Cont.) CHANGE POWER CORD CASE TRIM INSTALLATION Longer power cords are required for retro fit installation. Remove the stabilization brackets from the hinge side Power cords are included in 42” ZTKC42 and 48” of each column refrigerator by removing 4 Phillips head ZTKC48.
  • Page 26: Step 6 Connecting Water Supply

    Installation Instructions - Dual Retro-Fit Installation STEP 5 JOINING DUAL INSTALLED STEP 6 CONNECTING WATER UNITS (Cont.) SUPPLY CASE TRIM INSTALLATION Connect to potable water supply WARNING only. Fit the top trim and side trim rails together by sliding the exposed edges of the corner trim into the right and left trim kit side rails.
  • Page 27: Step 7 Inserting/Securing Into Cabinet Surround

    Installation Instructions - Dual Retro-Fit Installation STEP 7 INSERTING/SECURING INTO CABINET SURROUND Plug both units to the outlet in the wall. WARNING Tip Over Hazard. WARNING Electrical Shock Hazard. These appliances are top heavy, especially with any doors open, and must be secured to prevent tipping To reduce the risk of electrical shock, be careful forward which could result in death or serious injury.
  • Page 28: Step 8 Level Unit

    Installation Instructions - Dual Retro-Fit Installation STEP 8 LEVEL UNIT STEP 9 FINAL EXTERNAL UNIT PREPARATION (Cont.) All models have 4-point leveling. The front is supported by leveling legs; the rear is supported by adjustable Secure the trims to the surrounding cabinets to wheels.
  • Page 29: Step 10 Internal Unit Preparation

    Installation Instructions - Dual Retro-Fit Installation STEP 9 FINAL EXTERNAL UNIT STEP 11 START ICEMAKER PREPARATION (Cont.) (freezer models) Install front mullion and access cover trims between the 2 units. Open the doors and push the flexible CAUTION Avoid contact with the moving parts “dart”...
  • Page 30: Step 12 Install Autofill Pitcher Assembly

    Installation Instructions - Dual Retro-Fit Installation STEP 12 INSTALL AUTOFILL PITCHER ASSEMBLY (Some Refrigerator Models) Locate the AutoFill pitcher cover on the left side of the Conceal wires and tubing inside the wall compartment refrigerator’s interior. Remove T20 Torx screw holding and place the AutoFill assembly onto the forward end the cover in place towards the rear of the cover.
  • Page 31: Instructions For Single Integrated Installation

    Instructions for Single Integrated Installation New construction installation with 25” deep openings 31-49133-1...
  • Page 32: The Installation Space

    Design Guide - Single Integrated Installation SINGLE INTEGRATED INSTALLATION SPACE Dimensions in parentheses are in centimeters. 18” Integrated Freezer 30” Integrated Refrigerator 25" 25" 17 3/4" (63.5) 29 3/4" (63.5) (45.1) (75.6) 3 1/2" 3 1/2" (8.9) (8.9) Finished Finished Return Return 84"...
  • Page 33: Tools, Hardware, Materials

    Installation Instructions - Single Integrated Installation REFRIGERATOR/FREEZER LOCATION GROUNDING THE UNIT Do not install the refrigerator/freezer where the tem- WARNING perature will go below 55°F (13°C). It will not run Electrical Shock often enough to maintain proper temperatures. Hazard. Failure to follow these instructions can Do not install the refrigerator/freezer where result in death, fire, or electrical shock.
  • Page 34: Step 1 Remove Packaging

    Installation Instructions - Single Integrated Installation STEP 1 REMOVE PACKAGING STEP 2 INSTALL WATER LINE Connect to potable water supply WARNING WARNING only. Tip Over Hazard. These appliances are top heavy, especially with any A cold water supply is required for automatic doors open, and must be secured to prevent tipping icemaker and AutoFill pitcher operation.
  • Page 35: Step 3. Preparing Unit For Installation

    Installation Instructions - Single Integrated Installation STEP 3 PREPARING UNIT FOR STEP 4 INSTALL ANTI-TIP BRACKET Mount the anti-tip bracket centered about the mark INSTALLATION and flush to the floor as shown. Mark 3 holes for wall Place the unit in front of the installation opening in a mounting or 4 holes for floor mounting.
  • Page 36: Step 5. Connecting Water Supply

    Installation Instructions - Single Integrated Installation STEP 5 CONNECT WATER SUPPLY STEP 6 INSERTING/SECURING INTO CABINET SURROUND Connect to potable water supply WARNING Plug unit into the outlet in the wall. only. WARNING Electrical Shock Hazard. To reduce the risk of electrical shock, be careful during the remaining installation steps not to touch wiring or electrical components inside the compressor compartment while the appliance is...
  • Page 37: Step 7 Level Unit

    Installation Instructions - Single Integrated Installation STEP 6 INSERTING/SECURING INTO STEP 7 LEVEL UNIT CABINET SURROUND (Cont.) All models have 4-point leveling. The front is supported by leveling legs; the rear is supported by adjustable As you walk the unit back, pull the anti-tip strap tight. Secure the strap in the front of the unit.
  • Page 38: Step 8 Final External Unit Preparation

    Installation Instructions - Single Integrated Installation STEP 8 FINAL EXTERNAL UNIT STEP 10 START ICEMAKER PREPARATION (freezer models) FOR FLUSH INSTALLATION: Make sure front surface of the door is 7/8” behind front face of CAUTION Avoid contact with the moving surrounding cabinets BEFORE securing brackets to parts of the ejector mechanism, or with the heating the surrounding cabinetry.
  • Page 39: Step 11 Install Autofill Pitcher Assembly

    Installation Instructions - Single Integrated Installation STEP 11 INSTALL AUTOFILL PITCHER ASSEMBLY (Some Refrigerator Models) Locate the AutoFill pitcher cover on the left side of Conceal wires and tubing inside the wall compartment the refrigerator’s interior. Remove the one T20 Torx and place the AutoFill assembly onto the forward end screw holding the cover in place towards the rear of of the mount until flush with the interior wall of the...
  • Page 40: Reversing The Door Swing

    Reversing the Door Swing This step can be done for all installation types. 31-49133-1...

Table of Contents