This conversion kit must be installed by an Empire Comfort Systems, distributor (or other qualified agency¹)*in
accordance with the manufacturer's instructions and all codes and requirements of the authority having
jurisdiction. Failure to follow instructions could result in serious injury or property damage. The qualified
agency performing this work assumes responsibility for this conversion.
1National Fuel Gas Code Z223.1 (Latest Edition)
*The term "qualified individual, firm, corporation or company which either in person or through a representative
is engaged in and is responsible for (a) the installation of gas piping or (b) the connection, installation repair,
or servicing of equipment, who is experienced in such work, familiar with all precautions required, and has
complied with all the requirements of the authority having jurisdiction.
CHECK SAFETY SHUTDOWN PERFORMANCE
Perform the safety shutdown test anytime work is done on a gas system to avoid the possibility of fire or explosion
with property damage, personal injury or loss of life.
SAFETY SHUTDOWN SYSTEM
Intermittent Pilot System
1. Turn "OFF" using remote control. Main burner and pilot should go off.
2. Pilot gas flow should stop within 30 seconds.
PART DESCRIPTION
Main Burner Orifice, Front
Main Burner Orifice, Rear
SIT Gas Valve Conversion Kit
Gas Conversion Label
Tools Needed: Standard Screwdriver, 1/4 Inch Hex Driver, 5/16 Inch Hex Driver, 7/16 Inch Wrench, and 7/16 Inch Deep Socket Set
Gas input for direct vent fireplace converted to Propane Gas: DVCT36CFP95P - 39,500 BTU per hour
The direct-vent gas fireplace when converted to Propane gas will have a manifold pressure of approximately 10.0 inches
w.c. (2.49kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 10.8 inches w.c. (2.68kPa) for the
purpose of input adjustment to a maximum of 14.0 inches w.c. (3.484kPa).
37318-0-1116
GAS CONVERSION INSTRUCTIONS
DIRECT VENT GAS FIREPLACE
DVCT36CFP95N CONVERSION KIT PART NUMBER 37506
FOR CONVERSION TO PROPANE (LP) GAS
WARNING
WARNING
PARTS LIST
Empire Comfort Systems Inc. • Belleville, IL
CONVERSION KIT - 36884
P287
P208
R11382
1224
QUANTITY
SUPPLIED
1
1
1
1
Page 1