  • Page 1 UH-052XR Operating Guide...
  • Page 2 WARNING! The UH052XR is splashproof* only when both the antenna and the battery are properly attached. Do not operate the transmitter of any radio equipment unless all the Radio Frequency (RF) connectors are secured and any open connectors are properly terminated. Do not operate the transmitter of any radio equipment near electrical blasting caps or in an explosive atmosphere.
  • Page 3: Table Of Contents

    Technical Support & Service ......2 Included in your UH-052XR Package ..... . 3 Getting Started Attaching the Antenna .
  • Page 4: Features

    INTRODUCTION The UH-052XR is a splash proof, portable two-way UHF-CB radio. It is compact, rugged and fits easily in your hand. This hand held UHF radio will give you consistent, outstanding performance in virtually all conditions and situations. To ensure that you get the most from the UH-052XR’s features, please read this operating guide carefully before...
  • Page 5: Technical Support & Service

    Toll Free 1300 366 895 Caution: Changes or modifications to this product not expressly approved by Uniden; or operation of this product in any way other than as detailed by this Operating Guide, can void your warranty and authority to operate this product.
  • Page 6: Included In Your Uh-052Xr Package

    INCLUDED IN YOUR UH-052XR PACKAGE UH-052XR Antenna AC Adaptor (AAD-052S) Wrist Strap Battery BP-052 (7.2V, 950mAh) Operating Guide Product Registration Card Note: If any of these items are missing from the box, contact your Uniden Dealer.
  • Page 7: Getting Started

    GETTING STARTED ATTACHING THE ANTENNA Attach the antenna to the UH-052XR following direction as indicated below. Be sure the antenna is firmly seated. ATTACHING THE BATTERY PACK 1. Slide the battery pack onto the bottom of the radio. 2. Use a coin to turn the screw that connects the battery pack to the UH-052XR.
  • Page 8: Battery Charge Indicator

    In this case, it is best to switch OFF the radio to help facilitate charging. UH-052XR will return to normal operation once enough power level is established. Note: If you are unable to charge a fully discharged battery, switch OFF the radio to avoid further discharging.
  • Page 9: Operation

    OPERATION When you press any key (except PTT), a short tone sounds. See the Controls and Indicators page at the back of this operating guide for button and key operations. POWER ON/OFF To turn the unit ON, rotate the clockwise until a “click” is heard. A channel number and battery level should appear on the display.
  • Page 10: Squelch

    This raises the ”Squelch Gate” so high that only the very strong signals can get through. (Make sure to first select a channel not in use before setting the squelch in your UH-052XR UHF-CB radio.) Turn fully counter clockwise until [SQ] you hear a hiss.
  • Page 11: To Transmit And Receive

    TO TRANSMIT AND RECEIVE The UH-052XR uses the 40 UHF-CB Channels. For your reference a list of the available channels and corresponding frequencies is printed at the end of this manual. 1. The maximum RF transmit power of UH-052XR is 5 watts.
  • Page 12: Using A Repeater Channel

    Repeater station and then re-transmitted at the same time on another channel. Your UH-052XR is designed with duplex capability on Channels 1 to 8. When any of these channels are set to operate in duplex mode during transmission, the UH-052XR automatically sends the signal at a frequency 30 channels above the original in order to access the repeater station.
  • Page 13: To Operate Uh-052Xr In Duplex Mode

    UH-052XR will return to simplex operation. SCANNING The UH-052XR has two types of scanning; Open Scanning (OS) and Group Scanning (GS), giving you flexibility and allowing you to use the radio more effectively. Scanning allows you to search for active channels programmed in the OS or GS memory.
  • Page 14: Group Scan

    Note: 1. If SCAN is deactivated while in an active channel, the UH-052XR will stay on that active channel. If no other channels are active, the UH-052XR will reinstate the starting channel. 2. Pressing [CTCSS] for 1.5 Secs. Will deactivate Open Scanning and activate CTCSS Scanning.
  • Page 15: Programming Scan Channels

    [ ], to select a lower channel DROP-OUT DELAY While scanning, the UH-052XR stops at a busy channel and receives a transmission. When the received signal is over, the unit will wait for 3 seconds for the return of the signal, otherwise, the radio resumes scanning.
  • Page 16: Built-In Vox

    [CTCSS] 3. During scanning and a signal is sensed on a CTCSS CH, the UH-052XR stops for about 400msecs (decode time) to decode the CTCSS code. If there is no code or the receive code does not match the one programmed on the unit, the unit resumes scanning.
  • Page 17 NOTE: VOX feature will not work without the Headset Microphone. Built in [PTT] of UH-052XR is temporarily disabled, however accidental pressing of [PTT] will cause the unit to transmit briefly. To activate VOX 1. Press and hold [VOX] 2. Press either [ ] or [ ] within 10 secs.
  • Page 18: Power Save

    SENDING CALL TONES The UH-052XR is equipped with two types of tones that user can use to alert other users or identify yourself prior to transmission. You can also apply the signal at the end of the transmission.
  • Page 19: Busy Channel Lock-Out

    BUSY CHANNEL LOCK-OUT(BCL) This feature prevents accidental transmission on a busy channel. This is recommended on channels where CTCSS is being used. If the channel is “active” and the signal is coming from a non or different CTCSS code user the BCL feature will prevent you from transmitting. To activate BCL Press and hold for 1.5 secs until...
  • Page 20: Battery Level Display

    BATTERY LEVEL DISPLAY icon in the top right hand corner of the screen indicates the UH-052XR current battery voltage level at all times. The battery level is displayed in 4 levels: LEVEL 4 Battery 100% full LEVEL 3 Battery approx 50% capacity...
  • Page 21: Uhf Channels And Frequencies

    UHF CHANNELS & FREQUENCIES Freq. Usage 476.425 Simplex/Duplex 476.450 Simplex/Duplex 476.475 Simplex/Duplex 476.500 Simplex/Duplex *476. 525 Simplex/Duplex 476.550 Simplex/Duplex 476.575 Simplex/Duplex 476.600 Simplex/Duplex 476.625 Repeater 476.650 Repeater #476.675 Back-up Emergency Channel 476.700 Repeater 476.725 Repeater 476.750 Repeater 476.775 Repeater 476.800 Repeater 476.825 Repeater...
  • Page 22: Ctcss Codes And Frequencies

    CTCSS CODES & FREQUENCIES Code No. Freq. (Hz) 00(‘oF’) 67.0 71.9 74.4 77.0 79.7 82.5 85.4 88.5 91.5 94.8 97.4 100.0 OPTIONAL ACCESSORIES • Battery (BP-052) • VOX Headset (VM-052) • Speaker Microphone (SM-050) • AC Adaptor (AAD-052S) • Cigarette Lighter Charger (CL-050) •...
  • Page 23: Technical Specifications

    SPECIFICATIONS General Channels Oper. Temp. Antenna Microphone Display Speaker Power Source Size Weight Transmitter Frequency Control Frequency Range Frequency Stability Power Output Spurious Emissions Current Drain Receiver Receiver Type Frequency Range Sensitivity @ 12 dB SINAD Squelch Sensitivity Audio Frequency Response (ref: 1KHz, ±...
  • Page 24 Charger Std. Power Supply Specifications shown are typical and subject to change without notice. AAD-052S Input 230~240V AC, 50Hz Output 9V, 210 mA Approval No. V/00031...
  • Page 25: Warranty

    Uniden, (F) Installed, programmed or serviced by anyone other than an authorised Uniden Repair Agent, or (G) Where the Serial Number label of the product has been removed or damaged beyond recognition.
  • Page 26: Controls & Functions

    CONTROLS & INDICATORS DC9V SCAN CTCSS MIC SPKR CTCSS OS/GS 1/5W LOCK UH-052XR...
  • Page 27 A. Transmit B. 1W Power C. Duplex Transmit D. Scanning E. Monitor F. Priority G. Busy Channel Lock Out H. Group Scanning I. Channel Numbers J. CTCSS Tone and VOX Levels 1. Antenna 2. Belt Clip 3. PTT (Push-to-talk) Switch 4.
  • Page 28 © 2000 Uniden Australia Pty Limited/Uniden New Zealand Limited Part Code UTZZ01872ZZ...