3. Response code / Error code

( 1 ) A CK r e p l y : 0 6 h
When the projector receives the Set, Increment, Decrement or Execute
command correctly, the projector changes the setting data for the specified
item by [Type], and it returns the code.
( 2 ) NA K r e p l y : 1 5 h
When the projector cannot understand the received command, the projector
returns the error code.
In such a case, check the sending code and send the same command again.
( 3 ) E r r o r r e p l y : 1 Ch + 0 0 0 0 h
When the projector cannot execute the received command for any reasons,
the projector returns the error code.
In such a case, check the sending code and the setting status of the projector.
( 4 ) D a t a r e p l y : 1 D h + x x x x h
When the projector receives the GET command correctly, the projector returns
the response code and 2 bytes of data.
NOTE • For connecting the projector to your devices, please read the manual
for each devices, and connect them correctly with suitable cables.
• Operation cannot be guaranteed when the projector receives an undefined
c o
m m a n d o r d a t a .
• Provide an interval of at least 40ms between the response code and any
other code.
• The projector outputs test data when the power supply is switched ON, and
when the light source is lit. Ignore this data.
• Commands are not accepted during warm-up.
• When the data length is greater than indicated by the data length code, the
projector ignore the excess data code. Conversely when the data length is
shorter than indicated by the data length code, the projector returns the error
code to the computer.
RS-232C Communication (continued)