Table of contents Basic data Section I 1. Hydraulic assembly A. Safety information B. Unpacking of water softener C. Checking hydraulic fittings at installation site D. Selecting installation site for the device E. Materials F. Regeneration washings discharge connection 2. Basic operations A.
Tip! Before installing the device, please read carefully this manual and comply with all safety rules related to commissioning and operation of the device. In case of any questions, please inquire with the service team of your of the device. Basic data Prior to connecting, commissioning and operation of the device, please fill in the following information: MOD.
Section I 1. Hydraulic assembly A. Safety information Before installing and The device can be supplied commissioning of the water together with a mechanical filter softener, please read carefuly this (optional), which should be manual. Compliance with the installed on the water pipe guidelines provided in the manual supplying water to the softener, in...
C. Checking hydraulic fittings at installation site Tap water pressure time it will exceed the maximum value In order for the water softener to of 8.0 bars. In this case, we function properly the pressure in the recommend to install a pressure water supply network must not be regulator.
garden CHECK water VALVE VALVE VALVE VALVE PRE-FILTER VALVE MANOMETER MANOMETER MANOMETER raw water Soft water WASHINGS OUTFLOW SAMPLING SAMPLING VALVE VALVE CONTROL VAVLE DEVICE BODY Fig. 2 Hydraulic connection of the water softener should be implemented in accordance with a specimen connection diagram shown in fig.
Page 8
insert thick end of the elbow pipe overflow hose of the brine tank to the connection piece from the serves only as additional outer side of the brine tank safety feature in case the filling of the brine tank with water is ...
If the code displayed on the seconds. screen is different than expected, please contact the supplier’s AQUAHOME 11-N should feature service team. the 11L code, while AQUAHOME Audio signaller (BIP): the signaller 17-N should feature the 17L code will activate each time the button ...
Page 10
Programming water hardness Single press of the “OK” button (in the Time mode) will cause the transition to the HARDNESS mode; the value flashing on the display screen should be 25 (default value). Then, it is necessary to code the hardness of used water in grains per American gallon - gpg (water hardness expressed in, for example, the German...
▲ or ▼ to set the new start time Pressing the “OK” button for the regeneration process. If a confirms the changes introduced. twelve-hour clock is set, please take note that the “ante mridiem With each pressing of one of the ▲...
C. Setting the desired water hardness number of the by-pass valve The standard by-pass valve, fitted on Soft water the water softener, features a water outlet Hard water hardness adjusting knob (fig. 5). The Extended inlet piston water hardness adjusting knob is used handle to adjust the hardness of softened Change in the...
Section II 1. Control panel functions A. Manual activation of regeneration process During operation of the water softener, it might be necessary to commence additional manual regeneration. Such additional regeneration process is required when: actual water usage exceeds the planned water usage (e.g.
B. Additional functions Programming the maximum period When activated (the display screen will between regenerations in days show the RECHARGE caption and, during water uptake idle period while the 97% and ON captions will Automatic regeneration during water flash alternately), the device will uptake idle period helps maintaining commence regeneration when the resin’s ion exchange capacity is used in...
caption. The digit will indicate the pressed, the display screen shows a number of days since the digit and the bottom of the screen commissioning of the water softener. shows the RECHARGE caption. The When the ▲ button is released, the digit will indicate the number of display screen will once again show regenerations carried out by the water...
Section III 1. Service activities control of the pre-filter’s cartridge The operation of the water softener is entirely automatic. cleanliness, periodical The basic maintenance activities for replacement of the cartridge which the user of the water softener is and/or control of the pressure responsible, include: upstream and downstream of the pre-filter - once a week or two...
B. Salt bridges Insert a stick into the tank to reach the salt bridge and Fig. 6 break it 2.5 – 5 cm Pen mark Salt Salt bridge Water level Stick, e.g. broom stick This phenomenon occurs when the handle) and place it near the device softener is installed in premises with (see figure no.
concerning the carrying out of the water hardness measurement are included in relevant water hardness tests (available at the water softener’s supplier or manufacturer). D. Control of water pressure in the installation Pay attention to the value of feed Please bear in mind that the control water pressure during operation of the program (including the conditions of water softener.
2. Operational recommendations Make sure to protect the device during operation against: excessive dusting of the water incidental possibility of a sudden softener installation site, heat source occurrence, too low and too high ambient incidental possibility of hot water temperature in the vicinity of the backflow (with temperature device - the temperature must...
Section IV 1. Technical specifications and dimensions Dimensions AQUAHOME 11-N AQUAHOME 17-N 48.0 cm A Total height 65.0 cm 82.2 cm B Height water 52.3 cm 69.5 cm INLET connections 30.2 cm 8.6 cm - Depth 48.0 cm 48.0 cm...
Section V 1. Control activities prior to contacting a service provider Important notice! 4. Check whether the transformer is Always keep this manual in the vicinity properly connected to an earthed of the water softener. socket and whether the connection cable is properly fitted.
2. Warranty card Authorised service provider: User: ........................................................This warranty card has been issued for the following device: Device name Type Serial number: AQUAHOME …………….. Ser. No: …………………………….. Water softener Warranty conditions: 1. The supplier grants the warranty of 4.
Page 24
the Supplier, the guidelines specified 6.5. damage resulting from herein, incorrect 7.2. carrying out assembly and operation, commissioning 6.6. damage resulting from of the device contrary to the improper storage guidelines, of the device and consumables, 7.3. failure to timely carry out 6.7.
3. Device commissioning protocol (original copy) - for the User Please contact the service team of the supplier or manufacturer in order to obtain more information on commissioning of the device. Place Date User Address: Tel. / fax: User Representative Details of the party carrying out the Full company name: commissioning...
4. Device commissioning protocol (copy no. 1) - for the Party commissioning the device Place Date User Address: Tel. / fax: User Representative Details of the party carrying out the Full company name: commissioning Address: Tel. E-mail: Device commissioned Mod. No: *Information on model number and serial number can be Ser.
Page 32
O-Ring, 23.8 x 30.2 mm 7170288 Part Turbine with a washer Part no. Description – 7113040 (includes 2x no. 722 and 1x 733 & 74) 7338111 Bolt, #6-199 x 3.3.5 cm (required 2) ↑ Turbine washer 7281291 Motor ↑ Turbine 7337474 Camshaft cover 7082053...
Impact of washings from water softener regeneration on municipal sewage systems and home sewage treatment plants. The regeneration process of the AQUAHOME ion exchange water softeners generates washings in the volume equivalent to 5% of the total volume of treated water, that are discharged to the sewage network.