Viessmann AQUAHOME 11-N Installation And Operation Manual

Viessmann AQUAHOME 11-N Installation And Operation Manual

Water softening station

Advertisement

Installation and operations manual
Water softening station
AQUAHOME 11-N
AQUAHOME 17-N
ENG

Advertisement

Table of Contents
loading

Summary of Contents for Viessmann AQUAHOME 11-N

  • Page 1 Installation and operations manual Water softening station AQUAHOME 11-N AQUAHOME 17-N...
  • Page 3: Table Of Contents

    Table of contents Basic data Section I 1. Hydraulic assembly A. Safety information B. Unpacking of water softener C. Checking hydraulic fittings at installation site D. Selecting installation site for the device E. Materials F. Regeneration washings discharge connection 2. Basic operations A.
  • Page 4: Basic Data

    Tip! Before installing the device, please read carefully this manual and comply with all safety rules related to commissioning and operation of the device. In case of any questions, please inquire with the service team of your of the device. Basic data Prior to connecting, commissioning and operation of the device, please fill in the following information: MOD.
  • Page 5: Section I

    Section I 1. Hydraulic assembly A. Safety information  Before installing and  The device can be supplied commissioning of the water together with a mechanical filter softener, please read carefuly this (optional), which should be manual. Compliance with the installed on the water pipe guidelines provided in the manual supplying water to the softener, in...
  • Page 6: Checking Hydraulic Fittings At Installation Site

    C. Checking hydraulic fittings at installation site  Tap water pressure time it will exceed the maximum value In order for the water softener to of 8.0 bars. In this case, we function properly the pressure in the recommend to install a pressure water supply network must not be regulator.
  • Page 7: Regeneration Washings Discharge Connection

    garden CHECK water VALVE VALVE VALVE VALVE PRE-FILTER VALVE MANOMETER MANOMETER MANOMETER raw water Soft water WASHINGS OUTFLOW SAMPLING SAMPLING VALVE VALVE CONTROL VAVLE DEVICE BODY Fig. 2 Hydraulic connection of the water softener should be implemented in accordance with a specimen connection diagram shown in fig.
  • Page 8  insert thick end of the elbow pipe overflow hose of the brine tank to the connection piece from the serves only as additional outer side of the brine tank safety feature in case the filling of the brine tank with water is ...
  • Page 9: Basic Operations

    If the code displayed on the seconds. screen is different than expected, please contact the supplier’s  AQUAHOME 11-N should feature service team. the 11L code, while AQUAHOME  Audio signaller (BIP): the signaller 17-N should feature the 17L code will activate each time the button ...
  • Page 10 Programming water hardness Single press of the “OK” button (in the Time mode) will cause the transition to the HARDNESS mode; the value flashing on the display screen should be 25 (default value). Then, it is necessary to code the hardness of used water in grains per American gallon - gpg (water hardness expressed in, for example, the German...
  • Page 11: Filling The Brine Tank With Salt

    ▲ or ▼ to set the new start time Pressing the “OK” button for the regeneration process. If a confirms the changes introduced. twelve-hour clock is set, please take note that the “ante mridiem  With each pressing of one of the ▲...
  • Page 12: Setting The Desired Water Hardness Value On The By-Pass Valve

    C. Setting the desired water hardness number of the by-pass valve The standard by-pass valve, fitted on Soft water the water softener, features a water outlet Hard water hardness adjusting knob (fig. 5). The Extended inlet piston water hardness adjusting knob is used handle to adjust the hardness of softened Change in the...
  • Page 13: Control Panel Functions

    Section II 1. Control panel functions A. Manual activation of regeneration process During operation of the water softener, it might be necessary to commence additional manual regeneration. Such additional regeneration process is required when:  actual water usage exceeds the planned water usage (e.g.
  • Page 14: Additional Functions

    B. Additional functions Programming the maximum period When activated (the display screen will between regenerations in days show the RECHARGE caption and, during water uptake idle period while the 97% and ON captions will Automatic regeneration during water flash alternately), the device will uptake idle period helps maintaining commence regeneration when the resin’s ion exchange capacity is used in...
  • Page 15: Power Outage

    caption. The digit will indicate the pressed, the display screen shows a number of days since the digit and the bottom of the screen commissioning of the water softener. shows the RECHARGE caption. The When the ▲ button is released, the digit will indicate the number of display screen will once again show regenerations carried out by the water...
  • Page 16: Service Activities

    Section III 1. Service activities  control of the pre-filter’s cartridge The operation of the water softener is entirely automatic. cleanliness, periodical The basic maintenance activities for replacement of the cartridge which the user of the water softener is and/or control of the pressure responsible, include: upstream and downstream of the pre-filter - once a week or two...
  • Page 17: Salt Bridges

    B. Salt bridges Insert a stick into the tank to reach the salt bridge and Fig. 6 break it 2.5 – 5 cm Pen mark Salt Salt bridge Water level Stick, e.g. broom stick This phenomenon occurs when the handle) and place it near the device softener is installed in premises with (see figure no.
  • Page 18: Control Of Water Pressure In The Installation

    concerning the carrying out of the water hardness measurement are included in relevant water hardness tests (available at the water softener’s supplier or manufacturer). D. Control of water pressure in the installation Pay attention to the value of feed Please bear in mind that the control water pressure during operation of the program (including the conditions of water softener.
  • Page 19: Operational Recommendations

    2. Operational recommendations Make sure to protect the device during operation against:  excessive dusting of the water  incidental possibility of a sudden softener installation site, heat source occurrence,  too low and too high ambient  incidental possibility of hot water temperature in the vicinity of the backflow (with temperature device - the temperature must...
  • Page 20: Technical Specifications And Dimensions

    Section IV 1. Technical specifications and dimensions Dimensions AQUAHOME 11-N AQUAHOME 17-N 48.0 cm A Total height 65.0 cm 82.2 cm B Height water 52.3 cm 69.5 cm INLET connections 30.2 cm 8.6 cm - Depth 48.0 cm 48.0 cm...
  • Page 21: Control Activities Prior To Contacting A Service Provider

    Section V 1. Control activities prior to contacting a service provider  Important notice! 4. Check whether the transformer is Always keep this manual in the vicinity properly connected to an earthed of the water softener. socket and whether the connection cable is properly fitted.
  • Page 23: Warranty Card

    2. Warranty card Authorised service provider: User: ........................................................This warranty card has been issued for the following device: Device name Type Serial number: AQUAHOME …………….. Ser. No: …………………………….. Water softener Warranty conditions: 1. The supplier grants the warranty of 4.
  • Page 24 the Supplier, the guidelines specified 6.5. damage resulting from herein, incorrect 7.2. carrying out assembly and operation, commissioning 6.6. damage resulting from of the device contrary to the improper storage guidelines, of the device and consumables, 7.3. failure to timely carry out 6.7.
  • Page 25: Device Commissioning Protocol (Original Copy)

    3. Device commissioning protocol (original copy) - for the User Please contact the service team of the supplier or manufacturer in order to obtain more information on commissioning of the device. Place Date User Address: Tel. / fax: User Representative Details of the party carrying out the Full company name: commissioning...
  • Page 27: Device Commissioning Protocol (Copy No. 1)

    4. Device commissioning protocol (copy no. 1) - for the Party commissioning the device Place Date User Address: Tel. / fax: User Representative Details of the party carrying out the Full company name: commissioning Address: Tel. E-mail: Device commissioned Mod. No: *Information on model number and serial number can be Ser.
  • Page 29: Component Drawings

    Section VI 1. Component drawings Head parts on a separate page...
  • Page 30 Clamp (required 2) 7295054 – 7112963 Head-cylinder connection o-ring 7155115 Brine well cover set (includes items 3-5) 7106962 Brine well, Aquahome 11-N ↑ O-Ring, 73.0 x 82.6mm 7263099 Brine well, Aquahome 17-N ↑ O-Ring, 20.6 x 27.0 mm – 7331672 Well assembly set (includes item ↑...
  • Page 31 Washer Seal Cross-section view...
  • Page 32 O-Ring, 23.8 x 30.2 mm 7170288 Part Turbine with a washer Part no. Description – 7113040 (includes 2x no. 722 and 1x 733 & 74) 7338111 Bolt, #6-199 x 3.3.5 cm (required 2) ↑ Turbine washer 7281291 Motor ↑ Turbine 7337474 Camshaft cover 7082053...
  • Page 33: Impact Of Washings From Water Softener Regeneration To Municipal Sewage Systems And

    Impact of washings from water softener regeneration on municipal sewage systems and home sewage treatment plants. The regeneration process of the AQUAHOME ion exchange water softeners generates washings in the volume equivalent to 5% of the total volume of treated water, that are discharged to the sewage network.

This manual is also suitable for:

Aquahome 17-n

Table of Contents