Viessmann AQUAHOME 20-N Installation And Operation Manual

Viessmann AQUAHOME 20-N Installation And Operation Manual

Water softening station
Table of Contents

Advertisement

Installation and operations
manual
for the device User
Water softening station
AQUAHOME 20-N / 30-N
1 / 2012
VIESMANN
Please retain this manual!

Advertisement

Table of Contents
loading

Summary of Contents for Viessmann AQUAHOME 20-N

  • Page 1 VIESMANN Installation and operations manual for the device User Water softening station • AQUAHOME 20-N / 30-N 1 / 2012 Please retain this manual!
  • Page 2 Important notice: The price of this device includes free of charge commissioning of the device to be performed by an authorised service provider. Transportation cost of a service technician is not included in the offer of free of charge commissioning of the device.
  • Page 3: Table Of Contents

    Regeneration washings discharge connection ..................... 1 2. Programming the control panels ............................1 Programming the control panel of Aquahome 20-N water softener ..............1 Programming the control panel of Aquahome 30-N water softener................1 Filling the brine tank with salt ..........................1 Setting the desired water hardness number of the by - pass valve ..............
  • Page 4: Basic Data

    Tip! Before installing the device, please read carefully this instruction and comply with all safety rules relating to commissioning and operation of the device. In case of any questions please inquire with the service team of your supplier or with the manufacturer of the device.
  • Page 5: Section I

    Section I 1. Hydraulic assembly A. Safety information  Before installing and the device, must not be higher commissioning of the water than 49 softener,, please read carefully  The device can be supplied this instruction Compliance with together with a mechanical filter the guidelines provided in the (optional), which should be instruction will ensure safe and full...
  • Page 6: Checking Hydraulic Fittings At Installation Site

    C. Checking hydraulic fittings at installation site  Tap water pressure time it will exceed the maximum value In order for the water softener to of 8.0 bars. In such case pressure regulator (pressure reducing valve) is function properly the pressure in the water supply network must not be recommended.
  • Page 7 the device and water “outflow” connection on its left side, when facing the device (figure 2). Figure Descriptions in English: - (above vertical hose in figure 1) -> raw water; garden watering water, shut-off valve; shut – off valve, pressure gauge; preliminary filter (option); pressure gauge; shut – off valve; pressure gauge; shut – off valve; check valve;...
  • Page 8: Regeneration Washings Discharge Connection

    F. Regeneration washings discharge connection Regeneration washings  place the rubber connecting piece discharge connection. in the hole of brine tank (from the  Use the hose supplied together bottom) in such way that part of with the device to connect the the connecting piece is located installation of washings discharge inside and part outside of the...
  • Page 9: Programming The Control Panels

    Commissioning of the device is included in its price. A. Programming the control panel of Aquahome 20-N water softener Figure Descriptions in English: display screen, LED indicating low salt level, “up” button, “down“ button, regeneration button (tonight – press; immediately (hold for 3 seconds), set/menu button ...
  • Page 10 Setting Time In order to set time, press ▲button to move ahead or ▼ button to set time back. If a twelve-hour clock is set, the “ante meridiem” (“AM”) caption will appear on the display screen for the after midnight part of the clock - hours between 0 and the "post meridiem”...
  • Page 11 water hardness number by 1. water hardness number by Pressing the ▲ button will increments of one unit. Between increase the displayed water water hardness numbers of 25 hardness number to the maximum and the maximum water hardness water hardness number for given number, the increments are 5 device.
  • Page 12: Programming The Control Panel Of Aquahome 30-N Water Softener

    Make sure to set the actual salt level each time the brine tank is refilled with salt. In order to cancel the salt level control feature, press ▲ or ▼ button until the display screen shows OFF. Pressing the “SET” button will confirm the changes introduced.
  • Page 13 In order to set time, press ▲button to move ahead or ▼ button to set time back. If a twelve-hour clock is set, the “ante meridiem” (“AM”) caption will appear on the display screen for the after midnight part of the clock - hours between 0 and the "post meridiem”...
  • Page 14 increase the displayed water increments of one unit. Between hardness number to the maximum water hardness numbers of 25 water hardness number for given and the maximum water hardness device. Between water hardness number, the increments are 5 numbers of 1 and 25, each units.
  • Page 15: Filling The Brine Tank With Salt

    the salt level in the brine tak to drop below that level. Important notice! Make sure to set the actual salt level each time the brine tank is refilled with salt. In order to cancel the salt level control feature, press “SET SALT LEVEL” button as many times as it is necessary for the display screen to show OFF.
  • Page 16: Setting The Desired Water Hardness Number Of The By - Pass Valve

    D. Setting the desired water hardness number of the by - pass valve Any standard by - pass valve, fitted on the water softener, features water hardness adjusting knob (blend adjusting knob; figure 5). The blend adjusting knob is used to adjust the hardness of softened water.
  • Page 17: Additional Functions Featured By Aquahome 20-N

    RECHARGE button again (but do not hold it). The RECHARGE TONIGHT caption will disappear from the display screen.  Important notice! B. Additional functions featured by Aquahome 20-N   SALT EFFICIENCY (Lower CLEAN FEATURE MINUTES salt consumption mode), (Duration of cleaning), ...
  • Page 18 period), sediments from the filtering mesh,  97% FEATURE (Automatic which is located in the main activation of the regeneration distributor. If the display screen shows (OFF), then use the ▲ or ▼ button to process after the ion exchange capacity of the resin has been used change it to (ON).
  • Page 19: Additional Functions Featured By Aquahome 30-N

    With factory settings (97 and OFF) that will begin to flash. This means this function is not active. When that the backwash duration time is set activated by pressing the ▲ or ▼ to 5 minutes. If the “SET” button is buttons (the display screen will show pressed again the display screen will alternately flashing 97 and OFF...
  • Page 20 Salt efficiency (reduced salt screen will show RECHARGE DAY consumption) mode caption. When the salt efficiency (reduced salt consumption) mode is ON, the Maximum period between device will run the regeneration regenerations in days during water process more often, consuming less uptake idle period salt and water for the process.
  • Page 21: Basic Diagnostics Data

    to 12-hour clock mode and vice show a light bulb symbol. If the versa. illumination switch is pressed again the illumination of the inside of the Backwash and fast rinse duration salt tank will be switched off. time Press again (but do not hold) the Water flow through the device SET button until the display screen If softened water is being uptaken...
  • Page 22: Protective Filtration (Cleansing)

    water flows through the device the show a number and the TIME or DAY display screen will show changing caption. The digit will indicate the values in the range between 000 number of days since commissioning of the water softener. When the ▲ and 199.
  • Page 23: Power Outage

    F. Power outage If electrical power to the water softener is lost, the display screen will turn off but the microprocessor will keep all settings for several hours. When electrical power is restored, verify and reset time, if the hour on the display screen is flashing or incorrect.
  • Page 24: Service (Maintenance) Activities

    Section III 1. Service (maintenance) activities  control of purity of filter screen of Operation of the water softener is entirely automatic. the preliminary filter, periodical Basic maintenance activities for which replacement of the filter screen the user of the water softener is and / or control of pressure responsible, include: upstream and downstream of the...
  • Page 25: Control Of Hardness Of Water Treated By The Water Softener

    water surface and creates an empty the brine tank. Then push the broom space between water and salt and handle down into the brine tank to its preventing their contact, hence salt bottom. If stronger resistance can be will not dissolve in water to make felt on the broom handle before it brine.
  • Page 26: Control Of Water Pressure In The Installation

    To eliminate any possible difference between current time and the time displayed by the device, follow the guidelines provided on page 9 (for Aquahome 20-N) or on page 12 (for Aquahome 30-N). 2. Automatic disinfection of the medium featured by Aquahome 30-N...
  • Page 27: Operational Recommendations

    used to regenerate the resin and use, the medium is disinfected and chlorine is used for its disinfection. the remains of free chlorine is The chlorine generated as a result of discharge into the drain together the electrolysis is safe for human with the regeneration washings.
  • Page 28: Troubleshooting Table

    5. Troubleshooting table Problem Cause (Reason) Removal (remedy) method Water softener No salt in the tank Refill salt supplies water that Activate manual regeneration is too hard or No power supply Restore power supply. Check entirely unsoftened displayed time. Activate manual regeneration Occluded outflow of sewage from Restore patency of washings...
  • Page 29: Section V

    Dimensions AQUAHOME 20-N/30-N A Total height 108.6 cm B Height of water connection points 94 cm - Depth 52.4 cm Width 43.8 cm - Inlet / outlet spacing 8.6 cm Water softener parameters AQUAHOME 20-N AQUAHOME 30-N Maximum water flow rate (m Water operating pressure range (bar) 1.4 - 8.0...
  • Page 30: Warranty Card

    (manual backwash filter) EPURION PLUS (automatic backwash filter) Water softener AQUAHOME 20-N Mod. No or AQUAHOME 30-N Ser. No * In case of a preliminary filter, if applicable, mark “x” in the column “Part name” next to the filter that has been provided with the device at the purchase.
  • Page 31  - resin tank - for the period of 5 notification by the User on years warranty inspection deadline. The  - control head - for the period notification should be submitted in of 3 years writing (via fax, email or regular ...
  • Page 32: Device Commissioning Protocol (Original Copy) - For The User

    Please contact the service team of the supplier or manufacturer in order to obtain more information on commissioning of the device. Distributor (vendor): VIESSMANN Sp. z o.o. Wrocław – phone no. 071/3607100, Komorniki – phone no. 061/8996200, Mysłowice – phone no.
  • Page 33 Data of the party carrying out commissioning Full company name: Address: Phone no.: E-mail: Device undergoing commissioning Mod. No: * Information on model number and serial number can be Ser. No: found on the label, accessible after lifting of the brine tank cover.
  • Page 34: Device Commissioning Protocol (Copy No. 1) - For The Party Performing Commissioning Of The Device

    4. Device commissioning protocol (copy no. 1) - for the party performing commissioning of the device Place (town) Date User Address: Phone / fax no.: Representative of the User Data of the party carrying out commissioning Full company name: Address: Phone no.: E-mail: Device undergoing commissioning...
  • Page 35: Device Commissioning Protocol (Copy No. 2) - For The Supplier Or Manufacturer

    5. Device commissioning protocol (copy no. 2) - for the Supplier or Manufacturer Place (town) Date User Address: Phone / fax no.: Representative of the User Data of the party carrying out commissioning Full company name: Address: Phone no.: E-mail: Device undergoing commissioning Mod.
  • Page 36: Section Vi

    Section VI 1. Components drawings head assembly components – see separate page...
  • Page 37 CATALOG CATALOGU DESCRIPTION DESCRIPTION NUMBER NUMBER Distributor O-Ring Kit (head + tank; Repl. Electronic Control Board (PWA), 7112963 7334303 includes 1-3) Model 20-N Repl. Electronic Control Board (PWA), O-Ring, 73.0 x 82.6 mm 7334311 including tank light, Model 30-N T4BEWTRE2 O-Ring, 20.6 x 27.0 mm Transformer 2024VB...
  • Page 39 CATALOGU CATALOGU DESCRIPTION DESCRIPTION NUMBER NUMBER Bolt #6 – 20 x 7/8 in. 7224087 7082053 Valve Body 7286039 Motor (includes no. 50) 7081201 Retainer, Nozzle & Venturi Bolt #6 – 20 x 3/8 in. 0900857 O-Ring, 6.4 x 9.5 mm 7231385 Motor plate 1202600...
  • Page 40: Impact Of Washings From Water Softener Regeneration To Municipal Sewage Systems And Home Sewage Treatment Plants

    Impact of washings from water softener regeneration to municipal sewage systems and home sewage treatment plants. The regeneration process of the AQUAHOME ion exchange water softeners generates washings in the volume equivalent to 5% of the total volume of softened water, that are discharged to the sewage network. Regeneration washings are tap water containing elevated levels of chlorides in the range between 100 and 155 mgCl/dm Discharge of washings containing the above referred amount of chlorides to municipal sewage systems is in...
  • Page 41: Conditions Of Technical Inspection Of Operation Of Pressure Devices, Fitted At Ion Exchange Water Softener Of Aquahome Type

    Conditions of Technical Inspection of operation of pressure devices, fitted at ion exchange water softener of AQUAHOME type. Pursuant to the Technical Inspection Act of December, 21st, 2000 (Journal of Laws no. 122, item 1321) as well as the Regulation of the Minister of Economy, Labour and Social Policy of July, 9th, 2003 (Journal of Laws no.

This manual is also suitable for:

Aquahome 30-n

Table of Contents