DCS Error Codes

To clear an error code on the DCS Control:
1. Turn DCS Power Switch to OFF.
2. Address/Fix the issue.
3. Turn DCS Power Switch to ON.
Error
E04: High Voltage (20VDC
or greater, measured
across battery posts)
E05: High Motor Current
(15 Amps or greater, mea-
sured on blue or brown
actuator wire)
E08: Low Voltage (7VDC
or lower, measured across
battery posts)
E09: Hall Sensor Error
E12: High Current (short
circuit, 60 amps or greater,
measured on red or black
wire between battery and
DCS Control)
E31: Home Button Error
E32: Zero Button Error
E33: Cut Depth Button
Error
E34: Up Button Error
E35: Down Button Error
32
Cause
Battery is damaged.
Engine voltage rectifier/regulator is damaged.
Actuator rod is stuck.
Too high of load.
Battery is low/dead.
Engine is not charging the battery.
Actuator Signal Cable is disconnected from DCS
Control or is damaged.
Actuator or DCS Control Board is damaged.
A wire or board component has shorted.
The Home Button is stuck or shorted.
The Zero Button is stuck or shorted.
The Cut Depth Button Error is stuck or shorted.
The Up Button is stuck or shorted.
The Down Button is stuck or shorted.
Solution
Replace battery.
Replace engine voltage rectifier/regulator.
Manually move the actuator rod using the
Manual Height Adjustment feature.
Ensure there is no binding anywhere on the
unit when the actuator is moving.
Charge battery.
Check the engine charging coil and voltage
rectifier/regulator. Replace or repair if
needed.
Check all connections. Repair or replace if
needed.
See flow chart, page 33.
Check all wires for shorts. If all wires are
okay, the DCS Control board may be dam-
aged and need to be replaced.
Check to see if Home Button is stuck. If not
stuck, replace the Home Button switch.
Check to see if Zero Button is stuck. If not
stuck, replace the Zero Button switch.
Check to see if Cut Depth Button is stuck. If
not stuck, replace the Cut Depth Button
switch.
Clear the error code.
If the error code reappears 30 seconds
after turning the Power Switch back ON,
the problem is the Up Button on the DCS
Control. Check to see if the Up Button is
stuck. If not stuck, replace the Up Button
Switch.
Clear the error code.
If the error code reappears 30 seconds
after turning the Power Switch back ON,
the problem is the Down Button on the
DCS Control. Check to see if the Down
Button is stuck. If not stuck, replace the
Down Button Switch.
3A7832A