error (word
n+9 bit 04)
Data other than BCD
An unrecorded phrase
exists in the message
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Voice Unit error flag (word n+9 bit 04)
In modes other than ON-LINE mode:
This flag performs the same operations as that of the ERR indicator. For in-
formation on the ERR indicator, refer to 5-1 Error Codes .
This paragraph should be an introduction to the level-1 section briefly ex-
plaining the contents and purpose of the section.
In ON-LINE mode:
When the ERR indicator on the Voice Unit is lit (i.e., when an error has oc-
curred in the memory or when no message is recorded), the Voice Unit error
flag operates as follows:
The Voice Unit error flag turns ON when the following conditions are met:
The output refresh is executed.
The number of repetitions (except F) and repeat intervals at which the mes-
sage is to be played back are not in BCD.
The 1st through the 16th message numbers are not in BCD.
The input refresh in the same I/O are is executed.
When the correct data is received during the subsequent output refreshing,
and when input refreshing in the same I/O refresh area is executed, the flag
turns OFF.
I/O refresh
OUT IN
Correct data
Battery error flag (word n+9 bit 05) (valid in all modes)
This flag turns ON during input refreshing, when the supply voltage of the
battery drops or when the battery is not correctly connected. It turns OFF
during input refreshing if the battery has been correctly connected or a new
battery has been connected.