Carrier Omnizone 50BVC Installation, Start-Up, Service And Controls Operation And Troubleshooting page 29

Water-cooled indoor self-contained systems
Table of Contents

Advertisement

AIRFLOW
0.2
(CFM)
RPM
WATTS
9,000
564
3,167
9,500
590
3,666
10,000
617
4,226
10,500
643
4,820
11,000
669
5,503
11,500
696
6,236
12,000
722
6,952
12,500
750
7,816
13,000
777
8,595
13,500
804
9,572
14,000
832
10,634
14,500
859
11,747
15,000
886
12,953
AIRFLOW
1.2
(CFM)
RPM
WATTS
9,000
751
4,663
9,500
771
5,264
10,000
792
5,963
10,500
812
6,603
11,000
833
7,388
11,500
854
8,199
12,000
874
8,921
12,500
896
9,855
13,000
919
10,857
13,500
941
11,918
14,000
964
13,064
14,500
987
14,269
15,000
1010
15,560
LEGEND
Bhp
— Brake Horsepower Input to Supply Fan
Watts — Input Power to Supply Fan Motor
NOTES:
1. Unit is available with the following motor and drive combina-
tions: 7.5, 10, 15, 20 hp standard drive; 7.5, 10, 15, 20 hp
medium-static drive; 7.5, 10, 15, 20 hp high-static drive.
For 7.5 hp standard drives, the drive range is 780 to 960 rpm.
For 10, 15, 20 hp standard and 7.5 hp medium-static drives, the
drive range is 805 to 991 rpm. For 10, 15, 20 hp medium-static
and 7.5 hp high-static drives the drive range is 960 to
1146 rpm. For 10, 15, 20 hp high-static drives the drive range is
1119 to 1335 rpm.
Table 20 — Fan Performance — 50BVT,V034
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.4
BHP
RPM
WATTS
BHP
3.76
605
3,483
4.13
4.35
629
3,999
4.74
5.01
655
4,584
5.44
5.72
678
5,194
6.16
6.53
704
5,901
7.00
7.40
729
6,577
7.89
8.34
754
7,380
8.85
9.38
780
8,260
9.91
10.49
806
9,050
11.04
11.68
832
10,043
12.25
12.97
859
11,122
13.57
14.33
885
12,217
14.90
15.80
911
13,474
16.44
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.4
BHP
RPM
WATTS
BHP
5.53
785
4,933
5.85
6.25
802
5,574
6.61
7.07
822
6,272
7.44
7.92
841
6,926
8.31
8.86
861
7,720
9.26
9.84
882
8,441
10.30
10.88
903
9,332
11.38
12.02
924
10,283
12.54
13.24
945
11,302
13.79
14.54
967
12,380
15.10
15.94
990
13,551
16.53
17.41
1011
14,765
18.01
18.98
1034
16,081
19.62
0.6
RPM
WATTS
BHP
RPM
645
3,798
4.51
683
667
4,331
5.14
704
691
4,933
5.85
726
713
5,583
6.62
747
737
6,298
7.47
770
761
6,987
8.38
792
784
7,798
9.36
815
810
8,561
10.44
839
835
9,504
11.59
863
860
10,514
12.83
887
886
11,610
14.16
912
911
12,756
15.56
936
936
13,996
17.07
961
1.6
RPM
WATTS
BHP
RPM
817
5,212
6.18
849
834
5,866
6.96
864
852
6,498
7.80
882
870
7,240
8.69
899
889
8,051
9.66
917
909
8,784
10.72
936
930
9,701
11.83
955
951
10,702
13.06
976
972
11,747
14.33
997
993
12,850
15.67
1018
1015
14,030
17.11
1040
1036
15,261
18.62
1060
2. Italics indicates field-supplied drive required.
3.
Do not operate in shaded area.
4. Static pressure losses must be applied to external static pres-
sure before entering the fan performance table.
5. Interpolation is permitted: extrapolation is not.
6. Fan performance is based on filter, unit casing, and wet coil
losses.
7. This unit has one supply fan and one fan motor.
29
0.8
1.0
WATTS
BHP
RPM
WATTS
4,112
4.88
718
4,392
4,671
5.54
738
4,977
5,282
6.27
761
5,654
5,963
7.07
780
6,263
6,612
7.93
802
7,005
7,388
8.86
823
7,798
8,225
9.87
845
8,510
8,990
10.97
868
9,427
9,949
12.14
891
10,403
10,985
13.40
914
11,447
12,097
14.76
938
12,585
13,260
16.18
962
13,765
14,517
17.71
986
15,038
1.8
2.0
WATTS
BHP
RPM
WATTS
5,512
6.54
881
5,804
6,166
7.31
895
6,394
6,804
8.16
911
7,118
7,563
9.07
927
7,885
8,253
10.07
944
8,578
9,127
11.13
962
9,469
10,060
12.27
981
10,420
11,079
13.51
1001
11,456
12,166
14.84
1022
12,551
13,303
16.23
1042
13,722
14,517
17.71
1064
14,979
15,765
19.23
1084
16,260
BHP
5.21
5.90
6.71
7.51
8.40
9.36
10.38
11.50
12.69
13.96
15.35
16.79
18.34
BHP
6.89
7.67
8.54
9.46
10.46
11.55
12.71
13.97
15.31
16.74
18.27
19.83

Hide quick links: