Assembly option PCB
7
Slide the fan unit forward from the appliance far enough to
access the basic pcb.
8
Mount the 6 pcb feet that came with the option pcb. Then
press the option pcb on the pcb feet and connect the 2
cables from the option pcb to the basic pcb (connector X12
and X13; see also §9.4 in the installation instructions CWL
300/400). Connect the desired options to the option pcb;
the top panel and feed the additional cables through those
out of the appliance.
2.2 Connections option pcb
5442-0
Heat Recovery unit CWL-300(B) / CWL-400(B) with option PCB
9
Slide the fan unit back into the appliance.
11 Place the heat exchanger back into the appliance.
the exchanger.
15 Switch on the appliance on the control panel (simultane-
ously press keys "OK" and "+" for 3 seconds).
dication must be reset by pressing key "OK" for 1 second.
The moment the option pcb is connected, it will automatically
be detected by the basic pcb.
A
=
Switching input for incident
C
=
Programmable make contact P1
D
=
Programmable make contact P2
E
=
Temperature sensor postheater
F
=
Input moisture sensor
G =
Input CO
sensor
2
J
=
Fuse postheater 4AT
K
=
Switching output postheater
L
=
Switching output preheater
M =
Fuse preheater 4AT